![background image](http://html1.mh-extra.com/html/smc-networks/mxqr-6/mxqr-6_operation-manual_1299195015.webp)
15
2-9 Mounting of auto switch
!
!
!
!
Caution
1) Auto switch mounting tool
For the tightening of the mounting screws (attached
to the auto switch), use a watchmaker’s
screwdriver with a handle diameter of about 5 to 6
mm.
2) Tightening torque
Tightening torque of auto switch mounting screws
Auto switch model
Tightening torque Nm
D-A9□(V)
0.10 to 0.20
D-M9□(V)
、
D-M9□W(V)
0.05 to 0.15
3. Maintenance
3-1 Precautions for maintenance
!
!
!
!
Warning
1) Maintenance should be performed according to the procedure indicated in the Operation Manual.
Improper handling can cause damage and malfunction of equipment and machinery.
2) Maintenance work
Improper handling of compressed air is dangerous. Therefore, replacement of elements and other
maintenance activities should be performed by personnel with sufficient knowledge and experience
pertaining to pneumatic equipment.
3) Draining
Remove condensate from air filters regularly.
4) Removal of equipment, and supply/exhaust of compressed air
When equipment is serviced, first confirm that measures are in place to prevent dropping of driven
objects and or equipment running out of control, etc. Then cut the supply pressure and the power of
facilities, and exhaust all compressed air from the system. Before restarting the equipment, confirm
that measures are taken to prevent sudden extension.
3-2. Addition of grease
!
!
!
!
Caution
1) Applying additional grease on the guide
Grease is applied to this product by the manufacturer, it is not necessary to apply further grease in the
life time of the product. If the grease is replenished, use the specified grease. (Specific grease part
number: GR-S)
2) Replacement of piston seal
A specific grease is prepared. Apply it to the piston seal and sliding part. (Specific grease part
number: GR-L)
Auto switch
Watchmaker’s screwdriver
(Attached to auto switch)
Auto switch mounting screw