4. 4 SIEMENS PLC S7 Connection Method
Below is an explanation of the LEC-GPR1 connection method with a SIEMENS PLX STEP7
TM
.
4.4.1 GSD File Installation
After STEP7TM has been stated.
Open[Hardware Configuration] screen.
Select “Opton-Install New GSD” From the mwnu var.
Select GSD File, and click the Open button.
After completiong the above steps,” Anybus-CC PROFIBUS DP-V1”will automatically be added to the
Hardware Catalog under the STE7TM[PROFIBUS DP][Additional Field Device][General]Folder.
* Screen data used on this document is taken for STEP7TM software by Siemens AG.
4.4.2 Adding Stations
Drag and drop “Anybus-CC PROFIBUS DP-V1”from the Hardware Catalogue to the station window.
[Properties-PROFIBUS interface”dialogue box will be displayed.
Enter the unit address on the dialogue boz.Please make sure that the address entered is the same as
the address set, using the switches.
Pree the OK button to confirm the address setting. “Anybus-CC PROFIBUS DP-V1”will be shown on
the station window.