background image

 

 

No.   

Introduction

 

Series IR1000 precision type regulator is superior in relief characteristics and constant pressure is 

kept in the case of flowing backward. 

IR10

0-F01-DII00467 is designated special for Sensatronic to be applied for respirator.

 

 

1.

 Specification

 

 

Model 

 

IR1000-F01-DII00467 

IR1010-F01-DII00467 

 

Max. supply pressure [bar] 

 

Max. 1.0 

(Note1)

 

Min. supply pressure [bar] 

 

Setting pr 0.5 

 

Setting pressure [bar] 

 

0.  05

0.1

 

Setting sensitivity 

 

(Note2) 

 

within 0.2% of full span 

 

Repeatability 

 

(Note2) 

within 

±

0.5% of full span 

(Note3)

 

Air consumption 

 

Less than 5 

l

/min (ANR)    (at supply pressure of 10bar) 

 

Fluid 

 

Air 

  Oxygen 

Ambient & fluid 

Temperature 

 

-10~50

  (With no freezing) 

 

 

Storage Temperature 

 

-20~70

  (With no freezing) 

 

Port size 

 

G1/8 

 

Pressure gauge port size 

 

G1/8 

 

Weight 

 

0.14 kg 

(Note 1)    With the condition of no flow on the output side. The min. differential pressure   
                  from setting pressure should be 0.5bar. 
(Note 2)    Full span specifies the max. setting pressure of product. (eg. IR1000: 2bar)   

(Note 3)    Air is normally being exhausted to the atmosphere.

 

 

 

 

-4- 

Summary of Contents for IR1000 Series

Page 1: ...No IR10 OM00006 PRECISION REGURETOR PRODUCT NAME IR1000 F01 DII00467 IR1010 F01 DII00467 MODEL Series...

Page 2: ...e of Contents Safety 2 3 Specifications 4 Operation principle 5 How to order 6 Production lot number symbol 6 Caution on handling 7 8 Troubleshooting 9 Spare parts list 10 Assembling drawing 11 Drawin...

Page 3: ...indicate the level of potential hazard by labeling Caution Warning or Damage To ensure safety be sure to observe ISO4414 Note 1 JIS B 8370 Note 2 and other safety practices DANGER In extreme conditio...

Page 4: ...r repair of pneumatic systems should be performed by trained and experienced operators 3 Do not service machinery equipment or attempt to remove component until safety is confirmed A Inspection and ma...

Page 5: ...2 0 1 4 Setting sensitivity Note2 within 0 2 of full span Repeatability Note2 within 0 5 of full span Note3 Air consumption Less than 5 l min ANR at supply pressure of 10bar Fluid Air Oxygen Ambient...

Page 6: ...drops the pressure balance of upper bottom part of diaphragms C collapses Then as the main valve closes the exhaust valve opens at the same time and the excess pressure from the downstream side is di...

Page 7: ...to product name plate PRECISION REGULATOR IR1000 F01 DII00467 MAX SUP PRESS 10bar OUTPUT PRESS 0 05 2bar MADE IN JAPAN Symbol of year Symbol of month January February March April May June July August...

Page 8: ...use compressed air which includes chemicals synthetic oils containing organic solvents salt or corrosive gases etc as this can cause damage of malfunction 3 If drains is not removed from air filters a...

Page 9: ...ure adjustment Caution Air supply 1 If the supply pressure line contains drainage or dirt etc the fixed throttle can become clogged leading to malfunction and therefore in addition to an air filter SM...

Page 10: ...r is not exhausted from bleed hole Fixed orifice is clogged Replace the component or fixed orifice Adhering dust to the sealing part of the main valve Remove the dust at the seat by replacing by the c...