background image

 

 

No.   

           
                     
                   

    Caution                  Operation 

   

(1) Do not use a precision regulator outside the range of its specifications as this can 

cause failure. (Refer to specifications.) 

(2) When mounting is performed, make connections while confirming port indications.   
(3) If a directional switching valve (solenoid valve, mechanical valve, etc. ) is mounted 

on the supply side of the regulator and repeatedly switched ON and OFF, wear of 
the nozzle/flapper section will be accelerated and a discrepancy in the setting value 
may occur. Therefore, avoid using a    directional switching valve on the supply side. 
In the event a directional switching valve will be    used, install it on the output side 
of the regulator.   

(4) Air/oxygen is normally discharged from the bleed port (the hole on the side of the 

body's  mid-section).  This  is  a  necessary  consumption  of  air  based  on  the 
construction of the precision regulator, and is not an abnormality.       

(5) Be sure to tighten the lock nut after pressure adjustment. 

 

                       

Caution                  Air supply

 

 

(1)  If  the  supply  pressure  line  contains  drainage  or  dirt,  etc.,  the  fixed  throttle  can 

become  clogged    leading to malfunction,  and  therefore,  in addition  to  an  air filter 
(SMC Series AF) be sure to use a mist separator (SMC Series AM, AFM). Refer to 
SMC's "Compressed Air Cleaning Systems" catalog regarding air quality.   

(2) Never use a lubricator on the supply side of the regulator, as this will positively 

cause the fixed throttle to become clogged and lead to malfunction. If lubrication is 
required for terminal devices, connect a lubricator on the output side of the 
regulator. 

 

                 

Caution                 

Piping 

 
(1)  Preparation before piping   

Before piping is connected, it should be thoroughly blown out with air (flushing) or 
washed to remove cutting chips, cutting oil and other debris from inside the pipe. 

        (2) Wrapping of pipe tape   

When connecting pipes and fittings, etc., be sure that cutting chips from the pipe 
threads and sealing material do not get inside. Further, when pipe tape is used, 
leave 1.5 to 2 thread ridges exposed at the end of the pipe/fitting. 

-8-

!

!

!

L

e

a

v

e

 

2

t

h

r

e

a

d

s

.

S eal  t ape

d

ie

re

c

t

io

n

R o

llin

g

Summary of Contents for IR1000 Series

Page 1: ...No IR10 OM00006 PRECISION REGURETOR PRODUCT NAME IR1000 F01 DII00467 IR1010 F01 DII00467 MODEL Series...

Page 2: ...e of Contents Safety 2 3 Specifications 4 Operation principle 5 How to order 6 Production lot number symbol 6 Caution on handling 7 8 Troubleshooting 9 Spare parts list 10 Assembling drawing 11 Drawin...

Page 3: ...indicate the level of potential hazard by labeling Caution Warning or Damage To ensure safety be sure to observe ISO4414 Note 1 JIS B 8370 Note 2 and other safety practices DANGER In extreme conditio...

Page 4: ...r repair of pneumatic systems should be performed by trained and experienced operators 3 Do not service machinery equipment or attempt to remove component until safety is confirmed A Inspection and ma...

Page 5: ...2 0 1 4 Setting sensitivity Note2 within 0 2 of full span Repeatability Note2 within 0 5 of full span Note3 Air consumption Less than 5 l min ANR at supply pressure of 10bar Fluid Air Oxygen Ambient...

Page 6: ...drops the pressure balance of upper bottom part of diaphragms C collapses Then as the main valve closes the exhaust valve opens at the same time and the excess pressure from the downstream side is di...

Page 7: ...to product name plate PRECISION REGULATOR IR1000 F01 DII00467 MAX SUP PRESS 10bar OUTPUT PRESS 0 05 2bar MADE IN JAPAN Symbol of year Symbol of month January February March April May June July August...

Page 8: ...use compressed air which includes chemicals synthetic oils containing organic solvents salt or corrosive gases etc as this can cause damage of malfunction 3 If drains is not removed from air filters a...

Page 9: ...ure adjustment Caution Air supply 1 If the supply pressure line contains drainage or dirt etc the fixed throttle can become clogged leading to malfunction and therefore in addition to an air filter SM...

Page 10: ...r is not exhausted from bleed hole Fixed orifice is clogged Replace the component or fixed orifice Adhering dust to the sealing part of the main valve Remove the dust at the seat by replacing by the c...

Page 11: ...22 FRANCE 33 1 64 76 1000 SPAIN 34 945 18 4100 GERMANY 49 6103 4020 SWEDEN 46 8 603 0700 GREECE 30 1 342 6076 SWITZERLAND 41 52 396 3131 HUNGARY 36 1 371 1343 TURKEY 90 212 221 1512 IRELAND 353 1 403...

Reviews: