background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Revision history 

 
 
 
 
 
 
 
 

 

 

       

URL http://www.smcworld.com

 

Phone 

AUSTRIA / (43) 2262-62 280   

 

ITALY / (39) 02-92711 

BELGIUM / (32) 3-355 1464   

 

NETHERLANDS / (31) 20-531 8888 

CZECH REP. / (420) 5-414 24611   

NORWAY / (47) 67 12 90 20 

DENMARK / (45) 70 25 29 00 

 

POLAND / (48) 22-548 50 85 

FINLAND / (358) 9-859 580   

 

PORTUGAL / (351) 2 610 89 22 

FRANCE / (33) 1-64 76 1000   

 

SPAIN / (34) 945-18 4100 

GERMANY / (49) 6103 4020   

 

SWEDEN / (46) 8-603 0700 

GREECE / (30) 1- 342 6076   

 

SWITZERLAND / (41) 52-396 3131 

HUNGARY / (36) 1-371 1343   

 

TURKEY / (90) 212 221 1512 

IRELAND / (353) 1-403 9000   

 

UNITED KINGDOM / (44) 1908-56 3888

 

 
Note:

 

Please acknowledge that this content might change without a previous notice beforehand. 

            Each company might be using the name of the commodity of this manual publishing respectively as a trademark. 
 

     

2004 SMC Corporation All Rights Reserved 

 

 

 

Summary of Contents for IR1000 Series

Page 1: ...No IR10 OM00006 PRECISION REGURETOR PRODUCT NAME IR1000 F01 DII00467 IR1010 F01 DII00467 MODEL Series...

Page 2: ...e of Contents Safety 2 3 Specifications 4 Operation principle 5 How to order 6 Production lot number symbol 6 Caution on handling 7 8 Troubleshooting 9 Spare parts list 10 Assembling drawing 11 Drawin...

Page 3: ...indicate the level of potential hazard by labeling Caution Warning or Damage To ensure safety be sure to observe ISO4414 Note 1 JIS B 8370 Note 2 and other safety practices DANGER In extreme conditio...

Page 4: ...r repair of pneumatic systems should be performed by trained and experienced operators 3 Do not service machinery equipment or attempt to remove component until safety is confirmed A Inspection and ma...

Page 5: ...2 0 1 4 Setting sensitivity Note2 within 0 2 of full span Repeatability Note2 within 0 5 of full span Note3 Air consumption Less than 5 l min ANR at supply pressure of 10bar Fluid Air Oxygen Ambient...

Page 6: ...drops the pressure balance of upper bottom part of diaphragms C collapses Then as the main valve closes the exhaust valve opens at the same time and the excess pressure from the downstream side is di...

Page 7: ...to product name plate PRECISION REGULATOR IR1000 F01 DII00467 MAX SUP PRESS 10bar OUTPUT PRESS 0 05 2bar MADE IN JAPAN Symbol of year Symbol of month January February March April May June July August...

Page 8: ...use compressed air which includes chemicals synthetic oils containing organic solvents salt or corrosive gases etc as this can cause damage of malfunction 3 If drains is not removed from air filters a...

Page 9: ...ure adjustment Caution Air supply 1 If the supply pressure line contains drainage or dirt etc the fixed throttle can become clogged leading to malfunction and therefore in addition to an air filter SM...

Page 10: ...r is not exhausted from bleed hole Fixed orifice is clogged Replace the component or fixed orifice Adhering dust to the sealing part of the main valve Remove the dust at the seat by replacing by the c...