background image

IDX-OM-X011 

Chapter

 1

 

Safety

 

IDF190D/240D Series 

1.1

Before Using the Air Dryer

 

 
 

1-1 

Chapter 1 Safety 

 
 
 

1.1  Before Using the Air Dryer 

  This chapter is intended to specifically describe the safety related issues for handling the product. 

Read this before handling the product. 

  This product is for dehumidification of compressed air. We, as the manufacturer, cannot take any 

responsibility    if used for any other purpose. 

  The product operates with high voltage and has some parts that get hot or rotates during operation. If 

a component needs to be replaced or repaired, contact a specialized vendor for parts and service. 

  All personnel who work with or around the product should read and understand the safety related 

information in this manual carefully before starting work. 

  This service manual is not a general safety manual. 

  People who handle this product or work around it need to take training to understand the inherent risks 

and master safety measures. 

  The safety manager is responsible for strictly observing safety standards, but responsibility in respect 

to safety standards during daily work resides with each individual operator and maintenance 
personnel. 

  Operators and maintenance representatives should take the safety of all    personnel in the work 

environment into account. 

  It is necessary to think of the safety of working place and work environment for each task. 

  If the product is subjected to a short power outage (including voltage sag), it may take a long time to 

resume normal operation or be unable to restart normally due to the protective equipment triggered 
after the power is recovered. Should this happen, turn the product off using the switch with lightand 
reset the protection circuits referring to 6.2 - Reset the Thermal relay and High Pressure Switch. It is 
possible that the product starts suddenly after the power is recovered. Turn off the switch with light 
when removing the cover panel. 

  This manual must be kept available to operators whenever necessary. 

 

1.1.1 

Danger, Warning and Caution in This Manual 

The instructions given in this manual aim to ensure that the product is operate in a safe and correct way. 
These instructions are grouped into three categories, “Danger, “”Warning”, and “Caution”, which indicate 
the  level  of  hazard,  damage  and  also  the  degree  of  emergency.  Read  these  statements  carefully  and 
thoroughly understand them and location of the instruction before operating or performing maintenance 
on  the  unit. 

DANGER

”,  “

WARNING

”  and  “

CAUTION

”  signs  are  in  order  according  to  severity 

(DANGER> WARNING> CAUTION). The meanings of these signs are as follows. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

Before using the product, be sure to read and understand all the 
important actions highlighted in this manual. 

"WARNING": Hazard that may cause serious personal injury or death during operation, 
maintenance or inspection due to the negligence of required procedure or warning to avoid 
the danger.

 

WARNING 

“DANGER": Hazard that will cause serious personal injury or death during operation, 
maintenance or inspection due to incorrect handling or negligence of compliance to avoid 
the danger.

 

DANGER 

"CAUTION": Hazard that Will cause minor personal injury or damage to the device or 
equipment during operation, maintenance or inspection due to the negligence of required 
procedure or warning to avoid the danger.

 

CAUTION 

Summary of Contents for IDF190D Series

Page 1: ...using the air dryer Keep the manual readily available for reference This manual is intended to explain the installation and operation of the product Only those who have thorough understanding of the...

Page 2: ...ems 2 JIS B8370 General rules for pneumatic equipment This manual is intended to explain the installation and operation of the product Only people who understand the basic operation of the product thr...

Page 3: ...installation 3 1 3 1 Transportation 3 1 3 2 Installation 3 2 3 2 1 Environment 3 2 3 2 2 Installation 3 2 3 2 3 Air piping 3 3 3 2 4 Replacement of auto drain 3 4 3 2 5 Electrical wiring 3 4 3 2 5 1 W...

Page 4: ...functions 7 5 Chapter 8 Option C 8 1 8 1 Specifications 8 1 8 2 Precautions for installation and handling 8 1 Chapter 9 Option M 9 1 9 1 Safety instructions for use 9 1 9 2 Specifications 9 2 9 3 Inst...

Page 5: ...protective equipment triggered after the power is recovered Should this happen turn the product off using the switch with lightand reset the protection circuits referring to 6 2 Reset the Thermal rel...

Page 6: ...occurs immediately stop the product and contact maintenance personnel or a qualified person The product has surfaces that can reach high temperatures during operation What is more there is also the da...

Page 7: ...1 specified products of the Act on Rational Use and Proper Management of Fluorocarbon in Japan It is strictly forbidden to emit Fluorocarbon to the atmosphere Before you repair this product you shoul...

Page 8: ...Cautions for Rotating Object 2 4 0 Front Since this product has parts that rotate during operation there is the danger of burn injury resulting from contact with them Though sometimes those parts can...

Page 9: ...y to dispose of collected refrigerant Only personnel with required knowledge and experience about the equipment and incidental device should perform the collection of the refrigerant Only maintenance...

Page 10: ...products Compliance Requirements 1 The use of SMC products with production equipment for the manufacture of weapons of mass destruction WMD or any other weapon is strictly prohibited 2 The exports of...

Page 11: ...eration Side ventilation grille air inlet Air intake for the fan to cool the condenser Do not block the grille by the wall Front panel mounting screw Provided on both sides Front Top ventilation grill...

Page 12: ...IDX OM X011 Chapter 2 Name and Function of Parts 2 1 Name and Function of Parts IDF190D 240D Series 2 2...

Page 13: ...safety of operators during the installation operation maintenance and checks of the product When the product is used for a critical facility or equipment prepare a spare product or alternative machine...

Page 14: ...e static electricity occurs or conditions which make the product discharge static electricity Avoid locations where high frequencies occur Avoid locations where damage is likely to occur due to lighte...

Page 15: ...ll an air tank Before piping flush the inside of piping to eliminate foreign matter such as particles seal tape or liquid gasket Entry of the foreign matter may cause cooling failure or drain discharg...

Page 16: ...pply cable 10AWG 5 5mm 2 or greater cable O D Approx 16mm 4 cores including the ground Approx 1 5m of cable is necessary for wiring in the product All electrical work must be carried out in a safe man...

Page 17: ...attached to the power cable and tighten it to the terminal block with the previously loosened screw Tightening torque 1 0N m 4 Mount the front panel back IDF190 240D 9 V 1 Remove the left panels 2 In...

Page 18: ...ve the front panel 2 Introduce the cable through the grommet with membrane to connect to the terminal block refer to the label on the terminal block Do not touch any equipment other than the terminal...

Page 19: ...utlet valve 3 Ensure that the ball valve of the auto drain is opened 4 Open the bleed valve of the auto drain When compressed air stops coming out press the flush button to confirm that there is no co...

Page 20: ...IDX OM X011 Chapter 3 Transportation and installation 3 3 Cautions about Reinstallation IDF190D 240D Series 3 8...

Page 21: ...air comes from the outlet Exhaust port Top ventilation 3 Open the IN and OUT side valves slowly Ensure the bypass valve is completely closed Confirm that there is no air leakage 4 The fan keeps starti...

Page 22: ...akage of compressed air Compressed air pressure temperature flow rate and ambient temperature are within the specifications of the product Confirm that drain comes out of the drain tube The evaporatio...

Page 23: ...re replacing or cleaning parts be sure to bleed compressed air remain inside of the product until the gauge indicates 0 Do not remove the auto drain case assembly with any air pressure remaining inter...

Page 24: ...ion cycles 5 2 3 Auto Drain Maintenance Remove the dust accumulated in the auto drain every month Use neutral detergent for cleaning When cleaning does not improve the operation replace the element an...

Page 25: ...er to D Replacement of the main valve 2 Wipe the inner surface of the housing with a cloth If there is dust stuck to the inside of the housing leakage can occur after reassembly 3 When O ring is dirty...

Page 26: ...condition in the refrigerant circuit with the table below a Check for refrigerant amount 1 Air bubbles may be generated if the refrigerant circuit on the upstream of the sight glass is clogged and pre...

Page 27: ...g without solving the problem can cause serious incidents Incorrect connection of 3 phase power supply Exchange the order of 2 wires out of the 3 wires R phase and T phase and reconnect them External...

Page 28: ...mperature low by ventilation Ventilation grille is obstructed by a wall or blocked with dust Install so that the ventilation grille is 1 0m or more away from the wall Clean the ventilation grille ever...

Page 29: ...Turn on the black stop switch of the product 2 Remove the front panel There is a thermal relay See Figure on the right 3 Make sure that the green bar appears in the display window of the thermal rela...

Page 30: ...IDX OM X011 Chapter 6 Troubleshooting 6 2 Reset the Thermal relay and High Pressure Switch IDF190D 240D Series 6 4...

Page 31: ...rant to be filled kg 2 48 4 5 Auto drain ADH4000 04 Port size 80A 3B JIS10KFF flange 100A 4B JIS10K flange Weight kg 450 660 Coating color Body panel White Base Black Applicable air compressor output...

Page 32: ...orcement of the Act on Rational Use and Proper Management of Fluorocarbons please visit our website below SMC s website https www smcworld com products ja freon 7 3 Dimensions Ventilation air outlet V...

Page 33: ...e relay TB Terminal block F Fuse SW1 Main unit remote selector switch SW2 Start switch SW3 Stop switch SW4 Remote operation switch Prepared by customer MC1 Electromagnetic contactor CM MC2 Electromagn...

Page 34: ...Fuse SW1 Main unit remote selector switch SW2 Start switch SW3 Stop switch SW4 Remote operation switch Prepared by customer MC1 Electromagnetic contactor CM MC2 Electromagnetic contactor FM RY1 Relay...

Page 35: ...y the condenser to become liquid When passing through the capillary tube the HFC gas is regulated and its temperature decreases While passing through the cooler part it evaporates rapidly taking the h...

Page 36: ...IDX OM X011 Chapter 7 Documents 7 5 Air and refrigerant circuits and functions IDF190D 240D Series 7 6...

Page 37: ...protected or insulated 8 2 Precautions for installation and handling 1 The epoxy resin minimizes the corrosion of the coated copper tubes against corrosive gas The corrosive cannot be completed preve...

Page 38: ...IDX OM X011 Chapter 8 Option C 8 2 Precautions for installation and handling IDF190D 240D Series 8 2...

Page 39: ...sted water that is discharged from the auto drain the waste liquid treatment is necessary Handle it following the bylaw or regulation of local government WARNING All electrical work must be carried ou...

Page 40: ...to drain standard Models Item IDF190 240D 3 M IDF190 240D 9 V M Product number IDF S0511 Maximum operating pressure 1 0MPa Fluid Compressed air Operation cycle 1 cycle per minute Operating time 2 sec...

Page 41: ...ype auto drain drain inlet port hex size 30mm in order Mount the auto drain vertically while facing the drain port downwards Allowable inclination difference in the vertical direction is 5 3 Screw in...

Page 42: ...IDX OM X011 Chapter 9 Option M 9 4 Electrical circuit diagram IDF190D 240D Series 9 4...

Page 43: ...al work must be carried out in a safe manner by a qualified person in compliance with applicable national regulations Be sure to shut off the user s power supply Wiring with the product energized is s...

Page 44: ...1 When the breaker is tripped please turn off the power supply and contact our service office White button indicates earth leakage has popped up Earth leakage White button indicates earth leakage has...

Page 45: ...tion record IDF60 70 80 90 Series 11 1 Inspection record 11 1 Chapter 11 Inspection record 11 1 Inspection record We recommend keeping the inspection record for maintenance or service Product No Descr...

Page 46: ...021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL https www smcworld com Note Specifications are subject to change without prior notice and any obligation on the part of the manufacturer 2020 SMC Co...

Reviews: