![background image](http://html1.mh-extra.com/html/smc-networks/idf100f-30-w-series/idf100f-30-w-series_operation-manual_1299703038.webp)
IDX-OM-M051
Air Dryer
4. Checks and Inspection
4.2 Parts requiring regular maintenance
4 - 6
IDF100F~150F-W
Danger
Use an aqueous solution of neutral detergent for cleaning
.
Do not use solvents like thinner.
Warning
When oils can enter the drained condensate, waste water treatment is necessary. Follow the
bylaws or rules of the local municipality for disposal.
Warning
Be sure to check air pressure is zero before replacing the element or performing the
maintenance of the auto drain.
As a preventive maintenance, press the flush button of the heavy-duty auto drain regularly to clean the
discharge valve (for flushing).
If operation failure occurs due to heavy dirt after the flushing, disassemble the auto drain and clean inside.
Also, shorten the time to the next flushing timing.
The pilot exhaust of the heavy-duty auto drain is at the position shown in the figure.
Do not close the
exhaust port.
Also, clean the exhaust port to prevent it from getting blocked by dust.
Flush button
Body
Bleed valve
Pilot exhaust port
open
close