13-2 Electrical Wiring
Output method
Output signal of Hyrodless Monosashi-kun is phase difference output of A phase / B phase (open
collector output) as shown in the figure below.
1 pulse signal is sent to both output terminals A and B at every 0.1mm travel of Hyrodless
Monosahi-kun.
Also maximum response time of sensor for Hyrodless Monosashi-kun is maximum 1500 mm/sec
(15Kcps) in cylinder speed.
Input / Output
Input / Output of Hyrodless Monosashi-kun is performed by connector came from sensor.
Signal
Symbol of contact Signal
A
A phase
B
B phase
C,D
COM (0V)
E
12V (Power supply)
F
0V (Power supply)
G
GND (Shield)
Reversed cylinder travelling direction
1
3
4
3
2
Counter value
0
1
2
0.7
Cylinder
stroke
mm
A phase output
pulse
B phase output
pulse
0.0
0.1
0.2
0.3
0.4
0.5
0.6
A phase
(white)
B phase
(yellow)
COM (0V)
(brown, blue)
Output circuit of Hyrodless Monosashi-kun