Chapter 11: Stopping Operation
11-1 Overrun (M L2 + Sequence controller)
The graph below shows the relation between piston speed and overrun.
(The length of overrun is changed by piston speed, load, tubing condition and control method. Be sure to
adjust the stop signal position, etc. by trial operation with the actual machine.)
11-2 Dispersion of stopping position
When cylinder is stopped intermediately, the stopping position is not fixed.
Dispersion of stopping position is changed by piston speed, load, tubing condition and control method,
etc. Please refer to the table below.
ML2 + Sequence controller
Piston speed
just
before stop
mm
/
s
100
300
500
800
1000
Stopping accuracy
mm
±0.5 ±1.0 ±2.0 ±3.0
±4.0
ML2 + CEU2
Piston speed just
before stop
mm
/
s
500
mm/s
Stopping accuracy
mm
±0.5
Start
Stop signal
Stop position
Idle
running
distance
Stop distance
(run)
(overrun)
Braking
distance
When cylinder is stopped inter-
mediately,
“idle running distance”
(from detection of stop signal to
beginning of brake operation)
and
“braking distance “(from beginning
of brake operation to slider stop) are
occurred as shown in the figure left.
0.5
1.0
Piston speed just before stop
m
/
s
No load
Load factor 50
%
100
50
T
h
e
l
e
n
g
th
o
f
o
v
e
rru
n
mm
Operating pressure 0.5MPa
Brake releasing pressure 0.3MPa
Mounting position Horizontal
Conditions
Operating pressure 0.5MPa
Brake releasing pressure 0.3MPa
Load factor 25
%
Summary of Contents for HYRODLESS MONOSASHI-KUN
Page 26: ...26 Chapter 8 External Dimension Drawing 8 1 Hyrodless Monosashi kun with brake scale ...
Page 27: ...27 8 2 With scale ...
Page 28: ...28 8 3 With brake ...
Page 29: ...29 8 4 With shock absorber ...
Page 30: ...30 8 5 With stroke adjustment unit X416 ...
Page 31: ...31 8 6 With stroke adjustment unit X417 ...
Page 32: ...32 Chapter 9 Construction Parts list ...
Page 42: ...42 ...