-77-
No.EX##-OMN0030-A
•Channel parameter object (1) (Class: 79h to 7Fh) [
DeviceNet
TM
extended object library 2]
Class Instance Attribute
Access
Name
Type
Value
79h
Open circuit detection
•SI
•Digital I(DX
□
C1)
•Digital O, I/O
BOOL
0=Disable
1=Enable
7Ah
ON/OFF count upper
limit detection
•SI
•Digital I, O, I/O
BOOL
0=Disable
1=Enable
7Bh
ON/OFF count upper
limit value
•SI
•Digital I, O, I/O
UINT
1 to 65000
(Times diagnosis is detected=Set
value x1000)
7Ch
Analog user set value
upper limit detection
•Analog I, O, I/O
BOOL
0=Disable
1=Enable
7Dh
Analog user set value
upper limit value
•Analog I, O, I/O
UINT
7Eh
Analog user set value
lower limit detection
•Analog I, O, I/O
BOOL
0=Disable
1=Enable
7Fh
01h to
0Ah
∗
1
64h to
83h
∗
2
Get/Set
Analog user set value
lower limit value
•Analog I, O, I/O
UINT
∗
1: 01h to 0Ah indicates the unit number 0 to 9.
∗
2: 64h to 83h indicates the channel number 0 to 31.