![SMC Networks EX600-ED Series Operation Manual Download Page 70](http://html1.mh-extra.com/html/smc-networks/ex600-ed-series/ex600-ed-series_operation-manual_1299354070.webp)
-69-
No.EX##-OMN0030-A
•System object (Class:66h) [
DeviceNet
TM
extended object library 1]
Instance
Attribute
Access
Name
Type
Description/Value
6Dh
Get
Number of units
USINT
Number of units connected
94h
Get
Unit Diagnostics 1
WORD
Bit0: Error is detected in unit 0
Bit1: Error is detected in unit 1
Bit2: Error is detected in unit 2
Bit3: Error is detected in unit 3
Bit4: Error is detected in unit 4
Bit5: Error is detected in unit 5
Bit6: Error is detected in unit 6
Bit7: Error is detected in unit 7
Bit8: Error is detected in unit 8
Bit9: Error is detected in unit 9
Bit10: Reserved
Bit11: Reserved
Bit12: Reserved
Bit13: Reserved
Bit14: Reserved
Bit15: Reserved
95h
Get
Unit Diagnostics 2
WORD
Reserved
96h
Get
Unit Diagnostics 3
WORD
Reserved
97h
Get
Unit Diagnostics 4
WORD
Reserved
98h
Get
Unit Connection 1
WORD
Bit0: Recognition of unit 0
Bit1: Recognition of unit 1
Bit2: Recognition of unit 2
Bit3: Recognition of unit 3
Bit4: Recognition of unit 4
Bit5: Recognition of unit 5
Bit6: Recognition of unit 6
Bit7: Recognition of unit 7
Bit8: Recognition of unit 8
Bit9: Recognition of unit 9
Bit10: Reserved
Bit11: Reserved
Bit12: Reserved
Bit13: Reserved
Bit14: Reserved
Bit15: Reserved
99h
Get
Unit Connection 2
WORD
Reserved
9Ah
Get
Unit Connection 3
WORD
Reserved
9Bh
Get
Unit Connection 4
WORD
Reserved
01h
79h Get/Set
Hold/Clear
BOOL
0=Switch
1=H.T. or DeviceNet
TM
Object