5. Specifications
Table 5-1 EX260-FPS1specifications
Item
Description
General
Dimensions (W x L x H) mm
28.2 x 102.4 x 78.0
Weight
200 g or less
Housing material
PBT
Rated voltage
24 VDC
Supply interruption for no loss of function
1 ms and less
Protection class
IP67 (when fully installed or fitted with protective cover)
(complies with IEC 60529)
Insulation resistance
10 Mega ohms or more between FE and other terminals.
(500 VDC is given between FE and all accessible terminals)
IEC 61131-2
Ambient temperature
Operation: -10 °C to 50 °C
Storage: -20 °C to 60 °C
Ambient humidity
35% to 85% RH (non-condensing)
Atmospheric pressure
Operation:80 kPa to 108 kPa (under 2000 m)
Storage: 66 kPa to 108 kPa (under 3500 m)
Vibration resistance
10 Hz to 57 Hz (constant amplitude) 0.75 mm
57 Hz to 150 Hz (constant acceleration) 49 m/s
2
2 hours for each direction X, Y and Z
EN 60068-2-6
Impact resistance
147 m/s
2
is given 3 times for each direction X, Y and Z
EN 60068-2-27
Operating environment
No corrosive gas
Electrical
PWR
For logic
Operating voltage
24 VDC +20%/-15%
Under voltage detection
Detected: < approx. 19 VDC
Under voltage lockout
< approx. 16 VDC
Over voltage detection
> approx. 33 VDC
Over voltage lockout
(fuse blown)
> approx. 40 VDC
Internal current consumption at
24 VDC
0.2 A or less
PWR(V)
For valves
Operating voltage
24 VDC +20%/-15%
Under voltage detection
Detected: < approx. 19 VDC
Under voltage lockout
< approx. 16 VDC
Over voltage detection
> approx. 33 VDC
Over voltage lockout
(fuse blown)
> approx. 40 VDC
Max. current
1.3 A
Voltage drop to valve supply
Max. 1.2 V at 24 VDC
Protection against polarity reversal
Yes (PWR and PWR(V))
Galvanic isolation
Yes (between PWR and PWR(V))
2020-10-30 10:03
DL085648