4 - 48
4. PARAMETERS
No. Symbol
Name and function
Initial
value
Setting
range
Unit
Control mode
Position
Internal
speed
Internal
torque
PD02 *DI0 Input signal device selection 0(CN1-23
,
CN1-25)
Any input device can be assigned to the CN1-23 pin and CN1-25
pin(forward and reverse rotation pulse trains)
For the position control mode, position/internal speed change mode or
internal torque/position control change mode, CN1-23 pin is fixed to PP
or CN1-25 pin to NP. For the internal speed control mode or the internal
torque control mode,PP or NP can not be assigned.
CN1-23ピン(PP)の入力信号デバイスを選択
CN1-25ピン(NP)の入力信号デバイスを選択
The devices that can be assigned in each control mode are indicated by
abbreviation in the following table. If any other device is set, it is invalid.
262Dh
Refer to
the name
and
function
field..
○
○
Setting
Control modes (Note 1)
P
S
T
CP/CL
00
CN1-23 pin : PP
CN1-25 pin : NP
CN1-23 pin : PP
CN1-25 pin : NP
01
For manufacturer setting (Note 2)
02
SON
SON
SON
03
RES
RES
RES
04
PC
PC
05
(Note4)
EM1
EM1
EM1
06
For manufacturer setting (Note 2)
07
ST1
RS2
ST1
08
ST2
RS1
ST2
09
TL1
TL1
0A
LSP
LSP
0B
LSN
LSN
0C
For manufacturer setting (Note 2)
0D
SP1
SP1
0E
SP2
SP2
0F
SP3
SP3
10
LOP
LOP
11
CDP
CDP
12 to 1F
For manufacturer
setting (Note 2)
20
MD0
21 to 23
For manufacturer
setting (Note 2)
24
TSTP
25
For manufacturer
setting (Note 2)
26
DOG
27
PI1(Note 3)
28 to 2B
For manufacturer
setting (Note 2)
2C
DI0
2D
DI1
2E
DI2
2F to 3F
For manufacturer
setting (Note 2)
Input signal device of CN1-23 pin (PP) selection