8 - 12
8. TROUBLESHOOTING
Alarm No.: A.30
Name: Regenerative error
Description
Permissible regenerative power of the built-in regenerative resistor or the regenerative option is exceeded.
Regenerative transistor faulty in the driver.
Detailed
display
Detailed
Name
Cause
Checking method
Result
Action
30.1
Regenerative
heat
generation
error
1) Incorrect setting of the
built-in regenerative
resistor (regenerative
option)
Check the built-in
regenerative resistor
(regenerative option)
being used and the set
value of parameter No.
PA02.
The set value is
incorrect.
Set correctly.
The set value is
correct.
Check 2).
2) Built-in regenerative
resistor (regenerative
option) is disconnected.
Check if the built-in
regenerative resistor
(regenerative option) is
connected correctly.
Incorrect
connection.
Connect correctly.
Correct connection.
Check 3).
3) Power supply voltage is
high.
Check the input power
supply.
230VAC or more.
Decrease the power
supply voltage.
Below 230VAC.
Check 4).
4) The regenerative load ratio
is over 100%.
Call the status display
or software(MR
Configurator2
TM
) and
check the regenerative
load ratio at alarm
occurrence.
100% or more.
Reduce the frequency of
positioning.
Increase the deceleration
time constant.
Reduce the load.
Use the regenerative
option if it is not used.
30.2
Regenerative
transistor
fault
1) Regenerative transistor is
faulty.
Check if the built-in
regenerative resistor
(regenerative option) is
overheated abnormally.
Overheated
abnormally.
Replace the driver.
30.3
Regenerative
transistor
feedback
data error
1) Driver detection circuit is
faulty
Remove the wiring of P
and C, and execute the
operation.
Alarm occurs.
Replace the driver.