7 - 3
7. SPECIAL ADJUSTMENT FUNCTIONS
However, the overload tough drive function is not effective in the following cases.
(1) When the effective load ratio temporarily exceeds 200%.
(2) When the load increases at a stop such as a detent torque of a vertical lift.
Servo motor
speed
In-position (INP)
During tough
drive (MTTR)
Warning (WNG)
Trouble (ALM)
ON
OFF
Executes the optimum adjustment of the stop time
(INP delay time) Ti properly and avoids the overload
alarm (50.1) during the overload tough drive.
Effective
load ratio
Load ratio
increase
Load fluctuation
occurs
Overload alarm level
Overload tough drive start
Load fluctuation
normal status
Continuing
to drive
When the load ratio reduces,
automatically ends the INP
delay.
ON
OFF
ON
OFF
ON
OFF
Ti
Ti
Ti
When the overload tough drive function activates, the number of tough drive in the display mode (alarm mode)
is increased by one. (Refer to section 5.5.)
7.1.2 Vibration tough drive function
The vibration tough drive function reset the filter instantaneously and prevents oscillation when a machine
resonance is generated due to aging distortion or individual differences.
In order to reset the machine resonance suppression filter by the vibration tough drive function, parameters No.
PB13 (machine resonance suppression filter 1) and No. PB15 (machine resonance suppression filter 2) are
required to be set in advance. Perform either of the following to set parameters No. PB13 and No. PB15.
(1) Perform the one-touch tuning (refer to section 6.1).
(2) Set the parameters manually (refer to section 4.2.2).