ASSEMBLE FRONT PANEL

 

10

 

SELECT:

 

 

3 x 1.980 Wall Sheets

 

1 x 3.020 Top Plate (Red)

 

1 x 3.020 Bottom Plate (Green)

 

2 x 1.980 Door Jamb Flashings

 

40 x 30mm Galv Clouts

 

28 x Rivets

 

IMPORTANT—IF YOU CHOOSE TO RAISE YOUR TIMBER 

BASE PLATE –READ THE FOLLOWING;

 

 

For sheds with Raised Base Plate option only (see page 6), deduct 

30mm from measurement shown between Top and Bottom Plates on 
all wall panels, so cladding protrudes 20mm below bottom plate

.

 

STEP 1:

 

 

• 

Lay out 1 x Top Plate and 1 x Bottom Plate on a flat surface 
as shown. 

 

STEP 3:

 

 

• 

Place 3x Wall Sheets on timber, ensuring wall sheets fit under-
neath door jamb flashings. 

 

 

• 

Ensure that the top of the sheet is flush with the top of the Top 
Plate and that the sides of the wall sheets overhang the Top 
Plate by 

15mm

 as shown. Nail wall sheets to Top Plate (two 

clouts per pan)

 

 

• 

Nail the wall sheets to the Bottom Plate making sure that the 
Plates are the correct distance apart and that the sides of the 
wall sheet overhang the Bottom Plate by 

15mm

.

 

 

• 

Drill & rivet Door Jamb Flashings to wall sheets using four riv-

Plan View

 

STEP 2:

 

 

• 

Using 2 x 30mm clouts, nail the Door Jamb Flashing flush 
with the top of the Top Plate at the correct  measurement as 
shown in plan view. Pre drill holes using a 3.5mm drill bit

 

 

• 

Check the distance between the top and bottom plates then 
use a further 2 x 30mm clouts to nail the Door Jamb Flashings 
to the bottom Plate. Pre drill holes.

 

STEP 4:

 

 

• 

Place the door on the panel (In open position, approx 20mm 
below top of top plate). Using two rivets, rivet the top and bot-
tom hinges to the Door Jamb Flashing, ensuring door closes 
properly. 

 

 

• 

Fit remaining rivets.

 

NOTE: 

Door can be hinged on either side.

 

BOTTOM PLATE

 

1948mm

 

TOP PLATE

 

1948mm

 

530mm

 

1460mm

 

TOP PLATE

 

DOOR OPENING

 

TOP PLATE

 

TOP PLATE

 

15mm

 

15mm

 

x3

 

x3

 

TOP

 

PLATE

 

DOOR

 

JAMB

 

NAIL

 

15mm

 

15mm

 

x3

 

x3

 

x3

 

x3

 

NOTE: 

The

 

Doorway is standard at 530mm from left

-

hand end. 

To shift the doorway to the right

-

hand side of the front 

wall, simply measure 530mm from the right

-

hand end.

 

Summary of Contents for SM3015

Page 1: ...ASSEMBLY INSTRUCTIONS SM3015 BASE SIZE 3 020m x 1 520m...

Page 2: ......

Page 3: ...cess needs to be adhered to to qualify for the steel warranty of your Duratuf Smart store shed Wash all surfaces annually using a hose and soft nylon brush Within 2 km of coast wash every 3 months as...

Page 4: ...gle 1 935m 2 Side Wall Angle 1 905m 2 Roof 1 720m 6 Door Sheet Narrow 1 940m 3 Door Sides 1 940m 4 Door Jamb 1 980m 2 Door Brace 1 200m 2 Door Brace 0 955 2 Weatherstrip 1 940 1 Barge 1 720m 2 Door To...

Page 5: ...PACK 2 TIMBER DESCRIPTION QTY DIAGRAM Front Back Bottom Plates H4 Green 3 020 m 2 Front Back Top Plate H1 Red 3 020 m 2 Side Wall Bottom Plates H4 Green 1 520 m 2 Side Wall Top Plates H1 Red 1 522m 2...

Page 6: ...LE BACK PANEL 1 LAY FOUNDATION 2 ASSEMBLE DOOR QUICK OVERVIEW 3 ASSEMBLE SIDE PANELS Top Plat Barge Flashing Spouting Roof Sheets Top Plate Side Top Plate Front Bottom Plate Bottom Plate Front Wall Do...

Page 7: ...ng through from underneath During construction you may raise the bottom timber plate to allow the wall cladding to protrude 20mm below the bottom plate This will stop water flowing between the bottom...

Page 8: ...ans are on the outside Rivet sheets together ensuring ends are flush with each other STEP 2 Position door side flashings and 0 945m top and bottom flashings and assemble door as shown ensuring narrow...

Page 9: ...with bottom of sheets flush with each other Rivet sheets together on overlaps as shown STEP 3 Nail wall sheets to the Top Plate at each end making sure that the top of the sheets are flush with the t...

Page 10: ...sing two clouts per pan STEP 4 Nail the wall sheets to the Bottom Plate at each end ensuring that each side of the wall sheets overhangs the Bottom Plate by 15mm and that the distance between the Top...

Page 11: ...correct distance apart and that the sides of the wall sheet overhang the Bottom Plate by 15mm Drill rivet Door Jamb Flashings to wall sheets using four riv Plan View STEP 2 Using 2 x 30mm clouts nail...

Page 12: ...Using 2 x 40mm screws screw Top Plates together in the corner Using 2 x 40mm screws 2 per join screw the Bottom Plates together in the corner STEP 2 Repeat Step 1 with the second Side Panel ensuring...

Page 13: ...all Sheets fig 2 STEP 3 Ensure the Front and Back Top Plates are straight Screw the roof sheets to the front back Top Plates using 1 x Roofing Screw per rib fig 2 STEP 4 Place barge flashings on roof...

Page 14: ...N CORROSION AND COULD THEREFORE VOID THE WARRANTY FIT PADBOLT Rivet Padbolt to door and keeper onto Door Jamb as shown 13 YOUR DURATUF SMART STORE SHED IS NOW COMPLETE RELAX FITTING A SMART STORE FLOO...

Page 15: ......

Page 16: ...s less than 200g m2 as published by Branz Warranty certificate being returned to manufacturer within 21 days of purchase together with proof of purchase This warranty does not cover the following Fast...

Reviews: