Smart Power Systems
®
A. C. MODULAR GENERATOR SYSTEM
Page 13 of 52
WARNING:
Do not install hose ends until proper hose length has been determined.
Ensure debris is kept out of the hoses and hydraulic system prior to installation.
Never install a hose in a location where it will rub against another surface or
abrasion member.
Do not position hoses with tight bend radii. Consult the hose manufacturer’s
installation guidelines. Tight bends may kink and cause serious damage to the
system and will void the system’s warranty.
Use caution when tightening the hose ends to prevent the hose from becoming
twisted.
Never install a 90° fitting at the pump inlet or outlet. Avoid the use of flow
restricting fittings.
Do not form loops in the hose that may collect air or kink. Run hoses as straight as
possible (but not taut) between connections.
Do not exceed hose lengths of 20 feet.
Smart Power has fully tested and approved ISO fluids
ISO #32, #46 and #68 are approved for use in all Smart Power hydraulic generators.
Complete testing was performed using U.S. Oil Multi-Vis R Hydraulic Fluid under
controlled environments ranging from below freezing to above NFPA’s high temperature
requirements. The systems ran within our tight performance specifications using all three
listed grades.
ISO #32 is recommended when ambient temperatures are generally between 2 and 56°F.
ISO #46 is recommended when ambient temperatures are generally between 10 and
74°F.
ISO #68 is recommended when ambient temperatures are generally between 27 and
95°F.
For additional information on ISO fluids, contact U.S. Oils, or your local ISO grade fluid
supplier.