Smart Power Systems
®
A. C. MODULAR GENERATOR SYSTEM
Page 28 of 52
Operation
1.
The Command & Control Center will show the generator’s output voltage,
frequency, current, and system run time whenever the Command & Control Center
is in the Normal mode. To access Normal mode, press the Mode switch repeatedly
until the correct information is displayed (reference
Error! Reference source not f
ound.
4).
Figure 14
– Command & Control Center in normal mode
2.
The PTO driving the SPS hydraulic pump must be engaged for the system to
generate electricity.
3.
The Command & Control Center is equipped with two Smart Touch
switches,
labeled “Mode” and “On/Off” respectively. These switches do not require pressure
to be activated, but instead sense the presence or absence of your fingertip. The
decimal points in the “Amps Line 1” and “Amps Line 2” fields of the Command &
Control Center are used to indicate the status of the Mode and On/Off switches
respectively (reference
Error! Reference source not found.
5).
Mode Switch Status Light
On/Off Switch Status Light
Figure 15
– Switch Status Lights
Normally, the status lights will be off. When a switch is pressed, the
corresponding light will be illuminated. When a status light is flashing, the
corresponding switch is calibrating, and the switch should not be pressed.
The system controller will ignore the switch while it is calibrating.