Pump adjustment procedure:
1.
Enable the generator Pump Set option.
The system controller has been designed to provide a Pump Set option. With this
option applied, the generator will turn at the maximum speed allowed by the hydraulic
pump to allow proper adjustment of the pump’s flow.
The Pump Set option can be accessed by performing the following steps:
Step b: Hold Mode until
Amps Line 1 Blinks
.
Release switch so
appears.
Step c: Press mode twice
to make
appear.
Step d: After selecting
, Press On/Off until
appears.
Figure 31
– Enabling Pump Set Option
a. If the Command & Control Center is dark, press the Mode button to put the
Command & Control Center into Normal mode.
b. Press and hold the Mode button until the Amps Line 1 field blinks with
(more
than 10 seconds). Release the button while the Amps Line 1 field is blinking to
make
appear. Reference Figure 31.
c. Press (and release) the Mode button until
appears.
d. Press the On/Off button until a
appears, indicating Pump Set option is Active.
e. Return to Normal mode by pressing the Mode button until the screen shown in
Figure 32 is displayed. Pump Set will still be active.
Hours field alternates
between
and generator
status (
or
)
Actual Generator Output
Frequency
Figure 32
– Pump Set Display