No.

 

Items 

Description

 

Remark

 

AUX.OUTPUT2 

Relay Output2 

Default: MS2 Close Control; 

Volts free N/O output;   

Capacity: 250V16A   

AUX.OUTPUT3 

Relay Output3 

Default: MS1 Open Control; 

Volts free N/O output;   

Capacity: 250V16A 

AUX.OUTPUT4 

Relay Output4 

Default: MS2 Open Control; 

Volts free N/O output;   

Capacity: 250V16A 

AUX.OUTPUT5 

Relay Output5 

Default: BPS1 Close Control 

Volts free N/O output;   

Capacity: 250V16A 

10 

11 

AUX.OUTPUT6 

Relay Output6 

Default: BPS2 Close Control 

Volts free N/O output;   

Capacity: 250V16A 

12 

13 

LO 

ATS Power L 

Power supply for ATS switching   

14 

NO 

ATS Power N 

15 

A1 

S1 AC 3P4W voltage input 

For single phase, only connect A1, 

N1. 

16 

B1 

17 

C1 

18 

N1 

19 

A2 

S2 AC 3P4W voltage input 

For single phase, only connect A2, 

N2. 

20 

B2 

21 

C2 

22 

N2 

27 

B- 

DC negative pole 

Ground terminal 

28 

B+ 

DC positive pole 

DC(8-35)V input; controller power; 

29 

MAIN S1 CLOSE IN 

Detect S1 close status, volt 

free contactor input 

Ground connected is active. 

30 

MAIN S2 CLOSE IN 

Detect S2 close status, volt 

free contactor input 

Ground connected is active. 

31 

BYPASS S1 

CLOSE IN 

Detect BPS1 close status, 

volt free contactor input 

Ground connected is active. 

32 

BYPASS S2 

CLOSE IN 

Detect BPS1 close status, 

volt free contactor input   

Ground connected is active. 

33 

AUX. INPUT 1 

Digital Intput1 

Default: Forced Open 

Ground connected is active. 

34 

AUX. INPUT 2 

Digital Intput2 

Default: Breaker Trip Input 

Ground connected is active. 

35 

AUX. INPUT 3 

Digital Intput3 

Default: BTS Unlocked Status 

Ground connected is active. 

36 

AUX. INPUT 4 

Digital Intput4 

Default: ATS In Work 

Ground connected is active. 

37 

AUX. INPUT 5 

Digital Intput5 

Default: ATS In Test 

Summary of Contents for HAT880 Series

Page 1: ...SMARTGEN ZHENGZHOU TECHNOLOGY CO LTD HAT880 SERIES HAT880 HAT880S DUAL POWER BYPASS ATS CONTROLLER USER MANUAL...

Page 2: ...otocopying or storing in any medium by electronic means or other without the written permission of the copyright holder Applications for the copyright holder s written permission to reproduce any part...

Page 3: ...16 8 START STOP OPERATION 17 8 1 MANUAL START STOP 17 8 2 AUTO START STOP 18 9 PARAMETERS CONFIGURATION 20 9 1 ILLUSTRATION 20 9 2 PARAMETER CONFIGURATION TABLE 20 9 3 DIGITAL INPUT OUTPUT FUNCTION DE...

Page 4: ...phase power making correct judgment for abnormal power statuses over voltage under voltage loss of phase over frequency under frequency and outputting free voltage control signals After overall consid...

Page 5: ...rrent loss of phase inverse phase sequence protection functions Automatic Manual mode switchover In manual mode close or open can be controlled manually All parameters can be set on site Password vali...

Page 6: ...AC system 3P4W L L 80 530 V 3P3W L L 80 625 V DC supply 1P2W L N 50 305 V 2P3W A B 80 530 V Rated Frequency 50 60Hz Programmble Output 1 6 Relay Capacity 16A AC250V Volts free output Programmble Outpu...

Page 7: ...active Power kvar 10 Load 3 Phase Apparent Power kVA 11 Load Total Apparent Power kVA 12 Load 3 Phase Power Factor PF 13 Load Average Power Factor PF 14 Continuous Power Supply Time Currently 15 Conti...

Page 8: ...ing 1 time per sec when voltage is abnormal extinguished when S1 is no power S2 PWR S2 power indicator always illuminated when S2 is normal slow flashing 1 time per sec when voltage is abnormal exting...

Page 9: ...is waiting for Sync press again and it shall stop bypass S1 Sync close Bypass Open Active when main is locked bypass is unlocked in manual mode Press and bypass switch shall open Bypass S2 Close Acti...

Page 10: ...wer Q1 Q2 Q3 3 Phase Apparent Power kVA S1 S2 S3 Total Active Power kW sum of P1 P2 P3 Total Reactive Power kvar sum of Q1 Q2 Q3 Total Apparent Power kVA sum of S1 S2 S3 3 Phase Power Factor PF PF1 PF...

Page 11: ...6 S1 Under Volt Voltage is below the set lower value 7 S1 Over Freq Frequency is higher than the set upper value 8 S1 Under Freq Frequency is below the set lower value 9 S1 Loss of Phase Loss of one...

Page 12: ...ration time will be displayed 4 Scheduled Work When scheduled run is active its duration time will be displayed 5 S1 Cycle Run S1 cycle run countdown will be terminated when cycle start is active 6 S2...

Page 13: ...e After Sync conditions are satisfied MS2 Sync close outputs 14 Waiting MS1 PF Before MS1 is closed it s the delay time to confirm S1 PF Input signal is active 15 Waiting MS2 PF Before MS2 is closed i...

Page 14: ...rning alarm Fault alarms are active when controller detects the alarm signals Alarm indicator will flash rapidly 5 times per sec and the alarm will last until it was removed manually Fault alarms are...

Page 15: ...Up Down Confirm Return keys Table 15 Other Status Information No Item Description 1 Start Inhibit Genset start inhibit input is active 2 Remote Inhibit Remote control inhibit input is active 3 S1 Loa...

Page 16: ...et 7 Language 8 About Press Up Down key to choose parameters the current line was highlighted with black and then press Confirm key to enter into the corresponding display screen NOTE1 Default passwor...

Page 17: ...al i e start the genset When system is S1 Gens S2 Gens S3 Mains manual start stop menu interface is as follows Manual Test Genset Press Up Down key to choose parameters the current line was highlighte...

Page 18: ...er slave Gen Start Balance Gen Hours Not Used Cycle Gen Start When remote start is active S1 and S2 starts according to circular running time At the first time to start the genset choose S1 Start or S...

Page 19: ...ed there is no genset start signals output 8 2 3 SCHEDULED RUN Once Scheduled Run is enabled users can set the scheduled start time Controller will send start signal at preset start time Start signal...

Page 20: ...he delay from S1 voltage normal to abnormal 3 S2 Volt Normal 0 3600 s 10 The delay from S2 voltage abnormal to normal 4 S2 Volt Abnormal 0 3600 s 5 The delay from S2 voltage normal to abnormal 5 Maste...

Page 21: ...23 Set Value 0 200 90 Lower limit value of frequency it is abnormal if the value has fallen below the set value 24 Return Value 0 200 96 Lower limit return value of frequency it is normal only when t...

Page 22: ...le If close control is continous signal and this function is needed close time and open time are inactive 16 Sync Enabled 0 1 0 0 Disable 1 Enable 17 Volt Diff Enabled 0 1 0 0 Disable 1 Enable 18 Volt...

Page 23: ...from genset signal is sent to gen voltage is normal if delay is over and voltage is still not abnormal genset failt alarm occurs 7 Battery Volt Enable 0 1 0 0 Disable 1 Enable 8 Battery LV Warn Enable...

Page 24: ...November December Day 1 31 1 Date for not starting genset in each month 12 Inhibit Weekly Optional week Sunday Monday Tuesday Wednesday Thursday Friday Saturday 13 Inhibit Hours 0 23 h 0 Date of not s...

Page 25: ...ower Val 2 0 200 100 When load power is above the set value and delay is over unload control outputs 19 NEL OverPowerDelay2 0 3600 s 1 20 NEL Return Enable 0 1 0 0 Disable 1 Enable 21 NEL Return Value...

Page 26: ...1 Output NC 6 Relay Output 3 0 105 35 MS1 Open Control 7 Relay Output 4 Active Type 0 1 0 0 Output NO 1 Output NC 8 Relay Output 4 0 105 37 MS2 Open Control 9 Relay Output 5 Active Type 0 1 0 0 Outpu...

Page 27: ...1 Combined 2 Or Out 1 Active Type 0 1 0 0 Output NO 1 Output NC 32 Combined 2 Or Out 1 Contents Setting 0 105 0 Not Used 33 Combined 2 Or Out 2 Active Type 0 1 0 0 Output NO 1 Output NC 34 Combined 2...

Page 28: ...t Used 53 Combined 5 And Out Active Type 0 1 0 0 Output NO 1 Output NC 54 Combined 5 And Out Contents Setting 0 105 0 Not Used 55 Combined 6 Or Out 1 Active Type 0 1 0 0 Output NO 1 Output NC 56 Combi...

Page 29: ...0 RS485 2 Stop Bit 1 2 2 2 stop bits or 1 stop bit can be set 11 RS485 2 Parity 0 2 0 0 None Parity 1 Odd Parity 2 Even Parity 12 RS485 2 COM Set 0 3 0 0 Enable COMAdj Ctrl 1 Disable COMControl 2 Disa...

Page 30: ...close is inhibited if breaker is already closed users should open it manually In auto mode if breaker is already closed then close relay will deactivated or S2 take load 10 S2 Close Inhibit In manual...

Page 31: ...MS1 Close Key Same as MS1 Close key on the panel which is used to control S1 close and Self recover button shall be chosen 42 Main Open Key Same as open key of main switch which is used to control sw...

Page 32: ...larm is active annunciator can be connected externally When alarm mute input is active in input port or 60s delay has expired it can remove the alarm 16 Reserved 17 Genset Start Delay Output when star...

Page 33: ...eedback The close status of S1 switch 46 MS2 On Feedback The close status of S2 switch 47 S1 Genset Start When the system type is S1 Gen S2 Gen it controls the S1 genset start 48 S2 Genset Start When...

Page 34: ...bit Work Output during the Schedule Not Run process 88 Scheduler Gen Start Output during the Schedule Run process 89 Parallel Supply Both of S1 close for main and bypass switches when they are in work...

Page 35: ...hen OR condition output SW2 is active inactive close when active disconnect when inactive Contents of AND condition output SW3 output port 3 is active Close when AND condition output SW3 is active ina...

Page 36: ...ate and time Record type Event log S1 power supply status S2 power supply status S1 3 phase voltage S2 3 phase voltage S1 frequency S2 frequency Current IA IB IC Active power Power factor Maximum piec...

Page 37: ...ecord when S1 genset start signal is deactivated 14 S2 Genset Stop Record when S2 genset start signal is deactivated 15 Auto Mode Record when the genset mode transferred to Auto Mode 16 Manual Mode Re...

Page 38: ...or Maximum pieces of black box record are 5 Every event records all data information of this event in previous and backward 60s and record once per second The latest record will cover the oldest one w...

Page 39: ...pass Switch Mutual backup bypass switch means main switch and bypass switch can be backup mutually and main switch and bypass switch can separately be master and backup Table 22 Mutual And Dual Backup...

Page 40: ...o clear the alarm Transfer On Sync Fail When this is enabled after sync fails non sync close will be conducted and no sync failure alarm shall be issued Fail To Sync Delay Waiting time for sync it sha...

Page 41: ...3 3 MANUAL SYNC CLOSE When it is manual mode and S1 S2 power are normal if S1 is closed press S2 close key and S2 closes synchronously If S2 is closed press S1 close key and S1 closes synchronously I...

Page 42: ...whether the power is normal or not should be judged according to the AN voltage status of S1 and S2 and AC power voltage range The controller will intelligently control power supply when the power of...

Page 43: ...is NEL2 NEL1 Fig 7 NEL Control Sequence Drawing 14 3 MANUAL OPERATION If NEL manual trip input is active earthed failing edge is active NEL1 will trip without delay If NEL manual trip input is active...

Page 44: ...ring remote communication functions For details of communication protocol please refer to HAT880 Communication Protocol Communication parameters Module address 1 range 1 254 Baud rate 9600 bps 2400 48...

Page 45: ...N1 16 B1 17 C1 18 N1 19 A2 S2 AC 3P4W voltage input For single phase only connect A2 N2 20 B2 21 C2 22 N2 27 B DC negative pole Ground terminal 28 B DC positive pole DC 8 35 V input controller power...

Page 46: ...e Relay N O output Capacity 250V8A 47 48 AUX OUTPUT 10 Relay Output10 Default Not Used Volts free Relay N O output Capacity 250V8A 49 50 AUX OUTPUT 11 COM Relay Output11 Default Genset Start Volts fre...

Page 47: ...st CE1 CE2 switch is in work position Table 24 Remote Control Parameter Settings of Dual Bypass Partial Parameter Setting Bypass function type Dual bypass DBTSE Bypass switch type Remote bypass switch...

Page 48: ...TION Controller is panel built in design and it is fixed by clips when installed Fig 10 Overall Cutout Dimensions Fig 11 Clip Installation Drawing Installation Steps 1 Install 4 clip parts in turn and...

Page 49: ...recommended Auxiliary Output Error Check auxiliary output wiring and pay attention to N O contactor and N C contactor Check the output functions and output type settings in parameter settings Auxiliar...

Reviews: