18
SMARTEK Vision | User Manual
– LED Strobe Controller Family | Doc. v2.2.1
3.2. IPSC2
Figure 12: IPSC2
– Front panel view
Specification
IPSC2
Output channels
2
Asynchronous Operation
No timing independent channels
Operating Modes
Continuous, External Trigger, Internal Trigger,
Software Trigger, External Switch
Max. Voltage
200V (pulsed)
55V (continuous)
Max. current pulse (depending on
pulse width)
10A @ 200V per channel (20A total)
Max. continuous current
1A @ 30V per channel (2A total)
Maximum frequency
(External Trigger)
4,9kHz
Maximum frequency
(Internal Trigger Generator,
External Switch Mode)
997Hz
Pulse output range
1µs
– 1000ms in 1µs steps
Trigger input
0
– 5V or 0 – 24V level,
positive or negative edge (not opto-isolated)
Control interface
Ethernet (10BaseT)
Power requirements
12V
– 24V DC (min 11V, max 26V)
Power consumption
Max 3A @ 24V (72W)
Max 3,5A @ 24V (84W)
with additional heat sink
Housing
Black aluminum case
External dimensions
(H / W / L)
39 x 88 x 103 mm
Weight
approx. 285g
Storage temperature (ambient)
from -30°C/-22°F up to +80°C/+176°F
Operating temperature (ambient)
from -5°C/+23°F up to +50°C/+122°F
Conformity
CE, RoHS2
Table 12: IPSC2 - Specification