39
SMARTEK Vision | User Manual
– LED Strobe Controller Family | Doc. v2.2.1
Figure 28: ScLibClient
– Device List
If no controller is found, make sure every connection is plugged properly and the network
interface card is enabled. Further the firewall-settings might block packets from the strobe
controller and can be deactivated temporary for further investigation.
Invalid IP Address / Set IP Address
The strobe controller can have, for various reasons, an IP address that does not fit to the current
network configuration, which is thus invalid for establishing a connection.
Further, all strobe controllers are shipped in DHCP mode, without a preconfigured IP address.
In case no DHCP server is available in the network (peer-to-peer connection, switch, router
without DHCP activated), the IP address of IPSCx and HPSC1 devices is set to the invalid IP
address “0.0.0.0”, while HPSC1 v2, HPSC2 and HPSC4 devices receive an LLA address.
To change the IP address of the device to be on the same subnet as the IP address in the Local
Area Connection, click the
Set Address
icon.
Figure 29: ScLibClient
– Set IP Button
In the
Set Address
-window the new IP address, subnet mask, default gateway, DNS servers
and name of the controller can be set. Make sure to provide an IP address to the controller that
is not assigned to another device in the network.