APPENDIX E
REMOTELY MANAGING THE INTERACTIVE FLAT PANEL
82
SMART kapp iQ Pro 55
SMART kapp iQ Pro 65
SMART kapp iQ Pro 65-V2
SMART kapp iQ Pro 75
IMPORTANT
Do not use a null modem cable. Use only a standard RS-232 cable.
Configuring the computer’s serial interface
settings
Configure the computer’s serial interface before sending commands to the interactive flat panel.
To configure the computer’s serial interface
1. Turn on the interactive flat panel.
2. Turn on the computer, and then start the serial communications program or terminal emulation
program.
3. Activate local echo.
4. Configure the serial interface settings using the following values, and then press ENTER.
Baud rate
19200
Data length
8
Parity bit
None
Stop bit
1
A command prompt (>) appears on the following line, and the interactive flat panel can now
accept commands from the computer.
NOTE
If no message appears or an error message appears, the serial interface isn’t configured
correctly. Repeat steps 3 and 4.