Command
Command target range
Response
set red [value]
=0 to =100
red=[value]
set green [value]
=0 to =100
green=[value]
set blue [value]
=0 to =100
blue=[value]
set cyan [value]
=0 to =100
cyan=[value]
set magenta [value]
=0 to =100
magenta=[value]
set yellow [value]
=0 to =100
yellow=[value]
set videofreeze [target]
=on
=off
videofreeze=[target]
set cc [target]
=cc1
=cc2
=off
cc=[target]
N O T E
Typically,
cc1
displays English (U.S.) subtitles, while
cc2
displays other regional languages, such
as French or Spanish, depending on television channel or media setup.
Additional VGA source controls
Your VGA source supports all the general source controls described in
the previous page, as well as the commands listed in this section. These settings are unavailable
when the projector is in Standby mode or when the VGA sources are disconnected.
N O T E
Some of these commands are invalid with HDMI input and Composite video sources, and will
return the response “invalidcmd=[command]”.
These commands inform you of the current VGA source settings.
Command
Response
get frequency
frequency=[current frequency offset setting]
get tracking
tracking=[current tracking offset setting]
get saturation
saturation=[current saturation setting]
get tint
tint=[current tint setting]
get sharpness
sharpness=[current sharpness setting]
A P P E N D I X
B
Remotely managing your system through an RS-232 serial interface
84