Sensor Data Records
RTM-ATCA-747x-10G Installation and Use (6806800S80F)
55
Sensor Data Records
4.1
Sensor Data Records
The sensors available on the blades are detailed in the table below.
For sensor threshold definition please use the "ipmitool" found on
http://sourceforge.net/projects/ipmitool/files/ipmitool/
with
the parameter "sensor".
Table 4-1
Sensor Data Records
Sensor
Number
Sensor
Name
Sensor
Type
Event/
Reading
Type
Event
Data
Byte 1
Event
Data
Byte 2
Event
Data
Byte 3
Event
Threshold/
Description
Assertion
Deassertion
Rearm
52
+3.3V
RTM
Voltage
0x02
Threshold
0x01
Reading
Threshold
unr uc lnr lc
Asrt / Deass
Auto
53
+12V
RTM
Voltage
0x02
Threshold
0x01
Reading
Threshold
unr uc lnr lc
Asrt / Deass
Auto
54
+1.2V
RTM
Voltage
0x02
Threshold
0x01
Reading
Threshold
unr uc lnr lc
Asrt / Deass
Auto
55
+1.0V
RTM
Voltage
0x02
Threshold
0x01
Reading
Threshold
unr uc lnr lc
Asrt / Deass
Auto
56
temp in
RTM
Watchdog 2
0x23
Threshold
0x01
Reading
Threshold
uc unc
Asrt / Deass
Auto
57
temp SAS
Voltage
0x02
Threshold
0x01
Reading
Threshold
uc unc
Asrt / Deass
Auto
Asrt: Assertion Unr: Upper non-recoverable threshold Uc: Upper critical threshold Unc: Upper non-critical threshold