background image

 

RTM-ATCA-747x-10G 

Installation and Use
P/N: 6806800S80F

December 2020

Summary of Contents for RTM-ATCA-747x-10G Series

Page 1: ...RTM ATCA 747x 10G Installation and Use P N 6806800S80F December 2020...

Page 2: ...to the products described therein at any time without notice SMART EC makes no commitment to update the information contained within these materials Electronic versions of this material may be read o...

Page 3: ...nd Inspecting the Module 27 2 2 Environmental and Power Requirements 27 2 2 1 Environmental Requirements 28 2 2 2 Power Requirements 31 2 3 Installing the Hard Disk Module 31 2 4 Replacing the Hard Di...

Page 4: ...806800S80F Table of Contents 3 2 3 1 Ethernet Connectors 50 3 2 3 2 SAS Connector 51 3 3 ATCA Backplane Connectors 53 4 Sensor Data Records 55 4 1 Sensor Data Records 55 A Related Documentation 57 A 1...

Page 5: ...ure Sensors of RTM ATCA 747x 10G D Variant 1 30 Figure 2 3 Location of Temperature Sensors of RTM ATCA 747x 10G SP Variant 2 31 Figure 3 1 Mechanical Layout 45 Figure 3 2 Face Plate 46 Figure 3 3 Loca...

Page 6: ...List of Figures 6 RTM ATCA 747x 10G Installation and Use 6806800S80F...

Page 7: ...ble 1 2 Mechanical Data 26 Table 2 1 Environmental Requirements 28 Table 2 2 Critical Temperature Limits 29 Table 2 3 Power Dissipation 31 Table 2 4 SFP SFP Modules 38 Table 3 1 Face Plate LEDs 48 Tab...

Page 8: ...List of Tables 8 RTM ATCA 747x 10G Installation and Use 6806800S80F...

Page 9: ...page 27 outlines the installation requirements hardware accessories switch settings installation and removal procedures Chapter 3 Controls LEDs and Connectors on page 45 describes external interfaces...

Page 10: ...ard Disk Drive H S Hot Swap HPM Hardware Platform Management IANA Internet Assigned Numbers Authority ID Identifier IEC International Electric Code IEEE Institute of Electrical and Electronics Enginee...

Page 11: ...dustrial Computer Manufacturers Group RAID Redundant Array of Inexpensive Disks RoHS Restriction of Hazardous Substances RPM Rounds per Minute RTM Rear Transition Module RoHS Restriction of the use of...

Page 12: ...er Bold Used to characterize user input and to separate it from system output Reference Used for references and for table and figure descriptions File Exit Notation for selecting a submenu text Notati...

Page 13: ...hot surface that could result in moderate or serious injury Indicates an electrical situation that could result in moderate injury or death Indicates that when working in an ESD environment care shoul...

Page 14: ...the Declaration of Conformity Updated Related Documentation 6806800S80D July 2016 Removed declaration of conformity Updated copyrights information 6806800S80C September 2015 Updated Safety Notes on p...

Page 15: ...authorized to install remove or maintain the product The information given in this manual is meant to complete the knowledge of a specialist and must not be used as replacement for qualified personne...

Page 16: ...the blade Damage of Blade and Additional Devices and Modules Incorrect installation of additional devices or modules may damage the blade or the additional devices or modules Before installing or remo...

Page 17: ...your country s legislation and manufacturer s instructions SFP Modules Personal Injury and Damage of the RTM and SFP Modules Installing and using SFP modules which are not fully certified and which do...

Page 18: ...e Damage The optical port plug protects the optical fibres against dirt and damage Dirt and damage can render the SFP module inoperable Only remove the optical plug when you are ready to connect a cab...

Page 19: ...arf ausschlie lich f r Anwendungen in der Telekommunikationsindustrie und im Zusammenhang mit Industriesteuerungen verwendet werden Einbau Wartung und Betrieb d rfen nur von durch SMART EC ausgebildet...

Page 20: ...urchgehend leuchtet bevor Sie das Blade herausziehen Besch digung des Blades und von Zusatzmodulen Fehlerhafte Installation von Zusatzmodulen kann zur Besch digung des Blades und der Zusatzmodule f hr...

Page 21: ...t wird Umweltschutz Entsorgen Sie alte Batterien und oder Blades Systemkomponenten RTMs stets gem der in Ihrem Land g ltigen Gesetzgebung und den Empfehlungen des Herstellers SFP Modules Gefahr von Ve...

Page 22: ...sen ist Blicken Sie daher nicht direkt in die ffnung eines SFP Moduls um Verletzungen der Augen zu vermeiden Besch digung von SFP Modulen Die Schutzkappe eines SFP Modules dient dazu die sensible Opti...

Page 23: ...10G D offers the following features 4x10G interfaces using SFP modules Four 10 100 1000Base T Ethernet ports One hot swappable 2 5 SAS HD supported through on board SAS controller Two SAS ports to su...

Page 24: ...24 RTM ATCA 747x 10G Installation and Use 6806800S80F Introduction Introduction 1 2 Block Diagram Figure 1 1 shows the block diagram of RTM Figure 1 1 RTM Block Diagram...

Page 25: ...pport NEBS level three The compliance tests must be done with the customer target system PICMG 3 0 and 3 1 Defines mechanics blade dimensions power distribution power and data connectors and system ma...

Page 26: ...C341 P39 P40 R307 U105 CD452 U40 J4 P36 P35 P37 P38 R848 R321 R308 U59 R310 R314 R325 R330 D14 D15 D16 D17 CB77 R8 22 R751 R755 R756 R162 R163 R757 R761 R763 R767 R768 R771 R773 R654 C1 55 FB27 FB28...

Page 27: ...ing to your country s legislation 2 2 Environmental and Power Requirements In order to meet the environmental requirements the blade has to be tested in the system in which it is to be installed Befor...

Page 28: ...al limits Make sure the blade is completely dry and there is no moisture on any surface before applying power Blade Overheating and Blade Damage Operating the blade without forced air cooling may lead...

Page 29: ...ses 3 1 and 3 1E 5 to 95 non condensing According to Telcordia GR 63 CORE NEBS and EN 300 019 1 1 Classes 1 2 and 2 3 Vibration with HDD Installed 1g from 5 to 200Hz and back to 5Hz at a rate of 0 25...

Page 30: ...C1 61 C1 62 CD402 U76 R411 R412 R823 R690 R696 J16 U51 U103 C306 C309 C308 C307 L19 C304 C305 R630 R906 C243 C310 H31 R779 R775 U36 U86 R826 R829 R830 R833 R834 C323 C324 C325 C326 C344 U64 H30 R846 R...

Page 31: ...ormation on how to install the hard disk module The RTM is shipped with an HDD slot cover Figure 2 3 Location of Temperature Sensors of RTM ATCA 747x 10G SP Variant 2 AIR INLET TEMP PCIe SWITCH TEMP E...

Page 32: ...inserted 4 Tighten the two thumb screws of the hard disk module 5 Take all necessary steps in your operating system to make the hard disk operable the steps depend on the OS you are using 2 4 Replacin...

Page 33: ...eps depend on the OS you are using 3 Loosen the two thumb screws of the hard disk module 4 Pull the hard disk module outward by holding both screws and exerting equal force to keep it straight 5 Align...

Page 34: ...basic hot swap that means it can be installed removed and replaced in a powered system However after the RTM is installed or replaced in a powered system the front blade has to be rebooted so that the...

Page 35: ...to the shelf s rear which must be the same as that of the front blade 2 Ensure that the top and the bottom handles of the RTM are in an outward position by pushing the latch in the direction depicted...

Page 36: ...er each handle signaling a proper engagement in the shelf 7 Tighten both face plate screws on the RTM 8 Wait until the blue LED on the RTM is OFF A switched off blue LED indicates that the payload of...

Page 37: ...ormed about the desire of the blade to power down the payload of both the front blade and the RTM and the power down process is ongoing 2 Wait until the blue LED of the RTM is permanently ON A permane...

Page 38: ...gulations which correspond to the respective laser class apply to the whole RTM Not complying to these regulations may lead to personal injury When installing and using optical SFP modules which are c...

Page 39: ...SFP Module Procedure In order to install an SFP SFP module proceed as follows 1 Slide SFP SFP module into the slot until it locks into position The SFP SFP modules are not included as part of the RTM...

Page 40: ...optical port plug NOTICE SFP SFP Module Damage The optical port plug protects the sensitive optical fibres against dirt and damage Dirt and damage can render SFP SFP module inoperable Only remove the...

Page 41: ...TCA 747x 10G Installation and Use 6806800S80F 41 3 Connect the network cable to SFP SFP module 2 6 2 Removing an SFP SFP Module Procedure In order to remove an SFP SFP module proceed as follows 1 Remo...

Page 42: ...nd Installation Hardware Preparation and Installation 2 Open the SFP SFP latch Note that the latch mechanism of your SFP SFP module may be slightly different compared to the latch shown in the followi...

Page 43: ...ort plug NOTICE SFP SFP Module Damage The optical port plug protects the sensitive optical fibres against dirt and damage Dirt and damage can render the SFP SFP module inoperable Only remove the optic...

Page 44: ...44 RTM ATCA 747x 10G Installation and Use 6806800S80F Hardware Preparation and Installation Hardware Preparation and Installation...

Page 45: ...R870 C1 56 C1 57 C1 58 C1 59 C1 60 C1 61 C1 62 CD402 U76 R411 R412 R823 R690 R696 J16 U51 U103 C306 C309 C308 C307 L19 C304 C305 R630 R906 C243 C310 H31 R779 R775 U36 U86 R826 R829 R830 R833 R834 C32...

Page 46: ...keys and LEDs available at the face plate of the RTM variants Figure 3 2 Face Plate SMART EC RTM ATCA 747x 10G D RESET ETH1 1G 10G ETH2 1G 10G ETH3 1G 10G ETH4 1G 10G ETH5 6 1G ETH7 8 1G S A S H D D...

Page 47: ...ilable at the face plate Figure 3 3 Location of LEDs SMART EC RTM ATCA 747x 10G D RESET ETH1 1G 10G ETH2 1G 10G ETH3 1G 10G ETH4 1G 10G ETH5 6 1G ETH7 8 1G S A S H D D O O S I S A T N SMART EC RTM ATC...

Page 48: ...tus both in the early power state and the normal blade operation OFF Payload power is disabled Note This LED is multicolored red green yellow and is programmable by IPMC ATN Amber This LED is controll...

Page 49: ...n pressing it a hard reset is triggered and all attached on board devices are reset 3 2 3 Connectors The module provides the following connectors at its face plate Ethernet USB SAS Figure 3 4 Location...

Page 50: ...t 10 100 1000Base T interface connectors at its face plate The location of the Ethernet connectors is shown in the following figure Figure 3 5 Location of Ethernet Connector SMART EC RTM ATCA 747x 10G...

Page 51: ...nnector is shown in the following figure The RTM ATCA 747x 10G SP does not contain SAS connector Table 3 2 Ethernet Controller Types Front Panel Location Controller Count Ethernet Type ETH1 1G 10G Int...

Page 52: ...RTM ATCA 747x 10G Installation and Use 6806800S80F Controls LEDs and Connectors Controls LEDs and Connectors The pinout of the serial interface connector is shown below Figure 3 7 SAS Connector Pinou...

Page 53: ...R765 R874 U60 R784 R780 R235 R244 R3 97 R413 R414 R680 R699 R705 R764 R651 R657 R869 R870 C1 56 C1 57 C1 58 C1 59 C1 60 C1 61 C1 62 CD402 U76 R411 R412 R823 R690 R696 J16 U51 U103 C306 C309 C308 C307...

Page 54: ...54 RTM ATCA 747x 10G Installation and Use 6806800S80F Controls LEDs and Connectors Controls LEDs and Connectors...

Page 55: ...TM Voltage 0x02 Threshold 0x01 Reading Threshold unr uc lnr lc Asrt Deass Auto 53 12V RTM Voltage 0x02 Threshold 0x01 Reading Threshold unr uc lnr lc Asrt Deass Auto 54 1 2V RTM Voltage 0x02 Threshold...

Page 56: ...cted Asrt Auto Table 4 1 Sensor Data Records continued Sensor Number Sensor Name Sensor Type Event Reading Type Event Data Byte 1 Event Data Byte 2 Event Data Byte 3 Event Threshold Description Assert...

Page 57: ...Search at https www smartembedded com ec support or you can obtain electronic copies of SMART EC documentation by contacting your local sales representative Table A 1 SMART EC Documentation Document...

Page 58: ...58 RTM ATCA 747x 10G Installation and Use 6806800S80F Related Documentation Related Documentation...

Page 59: ...1...

Page 60: ...egistered trademark of SMART Modular Technologies Inc and SMART Embedded Computing and the SMART Embedded Computing logo are trademarks of SMART Modular Technologies Inc All other names and logos refe...

Reviews: