0 W 0x41A00 0x2C000620
0 W 0x01A00 8
0 W 0x11010 1702257011
*
6.
Make sure that there is one more line below “0 W 0x11010 1702257011” with no
characters at all.
7.
Go to “File” tab and select “Send file…”. Select the file
containing the PDO mapping
information, e.g. CBC-EIP_PDO_mapping.txt. This will send serial commands that are
necessary to configure the PDO mapping based on the .txt file.
•
No Ethernet data transfer between PLC and CBC-EIP
Most common reason is, if the System Macro V2.mlm file is not installed properly in the
destination folder. Refer to the section 2.2.1 for more information on installing the file
properly.
•
No ethernet communication
When the communication to the CBC-EIP controller is lost, it cannot be identified by any
health status led on the drive. But it can be identified either in the PLC module or through
the online web browser or using command prompt or using network connections window
below.