41
4.
Go to the “Setup” tab, then select “Serial port...”. Select a “Baud rate” of 115200 and
“Transmit delay” line of 1 msec/line
5.
Create a text file, e.g. CBC-EIP_PDO_mapping.txt containing all the text between * and *
below.
*
0 W 0x11600 0x2C001E20
0 W 0x01600 6
0 W 0x21600 0x2C001F20
0 W 0x01600 6
0 W 0x31600 0x2C002020
0 W 0x01600 6
0 W 0x41600 0x2C002120
0 W 0x01600 6
0 W 0x51600 0x2C002220
0 W 0x01600 6
0 W 0x61600 0x2C002320
0 W 0x01600 6
0 W 0x11A00 0x60410010
0 W 0x01A00 8
0 W 0x21A00 0x2C000420
0 W 0x01A00 8
0 W 0x31A00 0x60640020
0 W 0x01A00 8
0 W 0x51A00 0x60780010
0 W 0x01A00 8
0 W 0x61A00 0x60F40020
0 W 0x01A00 8
0 W 0x71A00 0x603F0010
0 W 0x01A00 8
0 W 0x81A00 0x2C000520
0 W 0x01A00 8