12 Troubleshooting
SMA Solar Technology AG
Operating manual
SHP-US-20-BE-en-10
70
Event number
Message, cause and corrective measures
7348
Incorrect file format
The configuration file is not of the required format or is damaged.
Corrective measures:
• Ensure that the selected configuration file is of the required format and is
not damaged.
• Retry import.
7349
Incorrect login rights for configuration file
The user group logged in does not have the user rights necessary to be able
to import a configuration.
Corrective measures:
• Log in as
Installer
.
• Import configuration file again.
7350
Transfer of a configuration file has started
The configuration file is being transferred.
7353
Update time zone database
The inverter is updating the time zone database.
7619
Communication fault with meter unit > Check communication to meter
The inverter is not receiving any data from the energy meter.
Corrective measures:
• Ensure that the energy meter is correctly integrated into the same network
as the inverter (see energy meter manual).
7702
7703
Self diagnosis > Interference device
The cause must be determined by the Service.
Corrective measures:
• Contact the Service.