Parameter Lists
SMA Solar Technology AG
150
SBU2200-TEN083320
Technical Description
20.4 Events, Warnings and Errors (History)
Information on events and error messages
[410# (Fail Current), 420# (Fail History) and 430#
(Event History)]
, are provided in section 21.4 „Display of Errors and Events“ (153).
20.5 Functions in Operation
510# Oper Inverter
Menu
no.
Parame
ter no.
Parameter name
Range/unit
Default
value
Description
510
01
InvRs
(Stby)
Restart
---
triggers inverter reset
510
03
InvTmOpEna
Disable
Enable
Disable
activates time-controlled inverter operation
510
04
InvTmOpStrDt
yyyymmdd
20060101
start date of time-controlled inverter
operation
510
05
InvTmOpStrTm
hhmmss
0
start time of time-controlled inverter
operation
510
06
InvTmOpRnDur
hhmmss
0
run time for time-controlled inverter
operation
510
07
InvTmOpCyc
Single
Daily
Weekly
Single
repeated cycle time for timer 1
510
09
CntRs
Inv
Bat
Gn
Gd
All
---
clears selected energy meter