INSTALL WALL PLATE ASSEMBLY
For Hardwire connection use.
i.
Using a wire stripper strip the two wire transformer connection from the conduit.
ii.
Insert the wire to the Blue Terminal Block provided with the Sensor Assembly
iii.
Tighten the terminal block screws using a flathead screwdriver 0.118” (3 mm) or smaller.
iv.
Connect the Blue terminal block to the two pins in the back of the Sensor Assembly.
IMPORTANT: SURGE PROTECTOR BEFORE THE TRANSFORMER IS RECOMMENDED
iii.
iv.
One EL-386 Transformer (sold separately) serves one (1) CX Closet/
Urinal flushometer.
One EL-451 Transformer (sold separately) serves up to (6) TruFlush
with 20 gauge wire within 50 feet
UNIT #2 THRU #10
(IF EL-451 USED)
THE SENSOR ASSEMBLY COMES WITH THE BUTTON
ALREADY INSTALLED. IN CASE THE BUTTON HAS COME
OFF FROM THE SENSOR ASSEMBLY DURING SHIPMENT,
INSTALL IT FOLLOWING THE FIGURE BELOW.