INSTALL WALL PLATE ASSEMBLY (CONT.)
A
B
B
C
D
Assemble C-Bracket to the wall bracket using two (2) 2” long
screws.Make sure screws are sticking out only about 1” behind the
C-Bracket.
Tighten two (2) locking nuts to the screws about ¼” away from tail
of the screws.
A
Rotate wall bracket slightly about vertical axis and slide C-Bracket
behind the finished wall while holding the top of the wall bracket.
Once C-bracket is behind the wall, align top two (2) holes on the
bracket to the wall box and secure in place using two (2) 2” long
screws. Tighten the bottom two (2) screws on the bracket.
Make sure the wall bracket is positioned plumb and level before
tightening the screws completely.
The Sloan CX sensor assembly is designed to work with both
hardwire and battery as a back-up or only the battery power
connection
Install the supplied batteries into the battery box.
Insert the Battery Box on the right side of the flushometer as shown.
INSERT SOLENOID
CONNECTOR HERE
C
Connect Battery Box D-shape connector to Sensor assembly.
NOTE: RED LED WILL START BLINKING WHEN POWER IS
CONNECTED TO THE SENSOR ASSEMBLY.
Mount the Sensor Assembly to the wall bracket.
i. Aligned the four (4) slots on the sensor assembly with the
mounting pegs on the wall bracket.
ii. Slide the sensor Assembly all the way down.
D
Insert flushometer solenoid connector to the sensor assembly.
E