8

FLUSHING WATER LINES

Note: Valve is shipped with flow adjustment turned off. Requires sensor assembly.

A

Ensure water is shut off: use adjustment tool to turn activation 
assembly fully clockwise.

B

Verify valve is not pressurized
         i.  connect solenoid to sensor assembly.  
         ii.  Connect battery pack.  
         iii.  Press override button.
Disconnect Solenoid from Sensor 
assembly

Press in activation assembly. 

E

Squeeze tabs on Collar and pull 
out.

F

Attached provided screws to 
activation assembly.  Pull to 
remove assembly

S

Remove conical spring.  Do not 
discard!  

Remove piston assembly by 
pulling straight out.  If unable to 
grip piston, remove screw from 
activation assembly and insert 
into center hole of piston.

J

Reinstall activation assembly 
and press until fully seated.  
Remove screws.

CLOSE

E1

E2

 B2

 B1

 C

 B3

  D

 D

 G

 H

G1

OPEN

CLOSE

G

Reinstall Collar.  Collar will 
spin freely in valve body when 
properly installed.

H

Using adjustment tool, turn 
activation assembly counter 
clockwise to open flow of water 
through the valve.

Push in activation assembly.

Squeeze tabs on Collar and pull 
out.

I

K

M

L

Reinstall piston.  Insert smaller sized end first until fully seated.

Reinstall conical spring, small end first, into piston.

Reinstall activation assembly and press until fully seated.

Reinstall orange collar securely.  Collar will spin freely in valve body 
when properly installed.

Adjust flow rate of valve as described in Section ADJUSTING FLOW

N

T

P

Q

R

CLOSE

E1

E2

 B2

 B1

 C

 B3

  D

 D

C

D

CLOSE

E1

E2

 B2

 B1

 C

 B3

  D

 D

CLOSE

E1

E2

 B2

 B1

 C

 B3

  D

 D

 G

 H

G1

OPEN

CLOSE

 G

 H

G1

OPEN

CLOSE

 G

 H

G1

OPEN

CLOSE

Once lines are flushed clear, turn 
activation assembly clockwise to 
shut off water.

 G

 H

G1

OPEN

CLOSE

N2

N1

 M

M

 R

 S

 P

 Q

N2

N1

 M

M

 R

 S

 P

 Q

Summary of Contents for CX 8158-1.28

Page 1: ...lushometers CX 8158 1 6 CX 8158 1 28 ITEMS INCLUDED VALVE BOX 1 Valve Box 2 Mud Guard 3 Adjustment tool 4 Mud Guard Screws 5 Activation Assembly Screws 6 Instructions 7 Adjustable Tube 8 Outlet Connec...

Page 2: ...ELECTED Consult fixture manufacturer for minimum pressure requirements Most Low Consumption water closets 1 6 gpf 6 0 Lpf require a minimum flowing pressure of 25 psi 172 kPa Model 8158 Closet Wall Hu...

Page 3: ...W FRONT VIEW Model 8158 Closet Floor Mount Rear Inlet Roughin for Sloan CX is determined relative to the spud connection for the fixture being used THIS PRODUCT CONTAINS MECHANICAL COMPONENTS THAT ARE...

Page 4: ...uard Metal C Bracket Wall Bracket Outlet Connection Gasket Poly Washer Elbow Poly Washer Coupling Adjustable Tube V500A RB Vacuum Breaker Assembly Vacuum Breaker Kit Valve Body Wall Box Shut off Sleev...

Page 5: ...T EXERT FORCE ON WALL BOX TO TIGHTEN FLUSHOMETER USED FIXED JAW WRENCH TO HOLD THE VALVE For hardwire use only remove wall box knock cap closest to the conduit connection E Using a sweat union not sup...

Page 6: ...secure it to the wall box Run transformer wires through the conduit to the wall box NOTE TRANSFORMER NOT PROVIDED IT IS VERY IMPORTANT THAT THE OUTPUT VOLTAGE OF THE TRANSFORMER BE 6VAC FOR THE UNIT T...

Page 7: ...eaker casing Flush Connection Wall opening 1 If needed trim urinal flush tube 2 Slide 3 4 coupling over urinal flush tube If cutting tube thread adapter first then cut After cut remove adapter to help...

Page 8: ...press until fully seated Remove screws CLOSE E1 E2 B2 B1 C B3 D D G H G1 OPEN CLOSE G Reinstall Collar Collar will spin freely in valve body when properly installed H Using adjustment tool turn activa...

Page 9: ...Blue terminal block to the two pins in the back of the Sensor Assembly IMPORTANT SURGE PROTECTOR BEFORE THE TRANSFORMER IS RECOMMENDED iii iv One EL 386 Transformer sold separately serves one 1 CX Clo...

Page 10: ...l bracket is positioned plumb and level before tightening the screws completely The Sloan CX sensor assembly is designed to work with both hardwire and battery as a back up or only the battery power c...

Page 11: ...seconds After 10 seconds step away from the sensor and listen for a CLICK The factory setting should be satisfactory for most installations If a range adjustment is required refer to the range adjustm...

Page 12: ...e Make sure Wall Plate doesn t slide up A B C OPERATION A continuous INVISIBLE light beam is emitted from the Sloan CX Sensor After the user enters the beam s effective range 22 to 31 inches 559 mm to...

Page 13: ...solenoid connector from the sensor assembly C Shut off water use adjustment tool to turn activation assembly fully clockwise Pass solenoid wire through center of tool to avoid damage Remove tool when...

Page 14: ...Times When User Steps Within Range Battery Only i Batteries low replace batteries F Red Light Blinks four 4 Times When User Steps Within Range Hardwire and Battery i Battery box not connected connect...

Page 15: ...306392PK Elbow 6 3306002 1 1 2 Coupling with S 21 Gasket 7 0306031PO 1 1 2 38 mm Flanged outlet tube RB 6 8 0396669PK F 102 1 1 2 38 mm Outlet Tube CP 8 9 0306238PK F 7 Flange CP 10 0306146PK F 5 A 1...

Reviews: