![Sleipner PJC211 User Manual Download Page 12](http://html1.mh-extra.com/html/sleipner/pjc211/pjc211_user-manual_1292865012.webp)
12
2917
14
2020
-
PJC 211 & 212
Information - PDC101 & PDC201
MC_0098
MC_0098
PDC101 and PDC 201
(Controller for AC electric thrusters)
Motor Speed: RPM on motor output shaft
Motor Power: Motor power consumption in % (PDC201 only)
Motor Temp: Temperature measured in motor
Thrust:
Thrust level from joystick/hold buttons
PDC-301
(SAC controller)
Motor : speed (rpm), temperature (°C/°F), power (kW), AC current (A) & AC voltage (V).
Thrust: Joystick thrust (%)
Information - PDC301
Panel Information
MC_0100
Display info about the control panel
FW:
Version number, Firmware
HW:
Version number, Hardware
S/N:
Serial number of the control panel
Voltage: S-link system voltage measured at the panel
•
Shows live update of S-link bus (CAN-bus) error status for the panel.
•
Showing no error and signal condition is good.
•
Example showing lots of error and very bad signal conditions.
DIAGNOSTIC DISPLAY
Rx Error Count
Receive error counter. Error during reception increments the value. After every successful reception the
value is decremented.
Tx Error Count
Transmit error counter. Error during transmit increments the value. After every successful transmit the
value is decremented.
Last Error
Indicates the error condition of the last error detected. If a message has been transferred or received
without error, it will show No Error.
Conditions: No Error, STUFF, FORM, ACK(Acknowledgment), BitRecessive, BitDominant & CRC.
Flag
BUS OFF: when Tx Error Count is greater than 255 and overflowed. (Tx Error Count will show 0 when in
BUS OFF state)
WARNING: when Rx Error Count or Tx Error Count has reached 96 counts
PASSIVE: when Rx Error Count or Tx Error Count is more than 127 counts
(NB: When S-link devices are hot plugged or disconnected to the bus or powered (when AMS is engaged
and powering PPC and retract), it is not unusual to see some values been incremented. But they will
quickly decrement to 0 again. This will not cause any communication issues.)
S-Link Diagnostic
MC_0100