15
EUTECTIC EC-10 DV
APPENDIX G
EC10DV SERIES BOILERS – INSTRUCTIONS TO REVERSE DOOR OPENING
Reverse the direction of opening of the burner
door.
When the boiler leaves the factory, the burner
door opens towards the right. To open the burner
door towards the left remove the boiler’s jackets
and perform the following steps:
1. Loosen the top and bottom nuts
1
with a
13mm open wrench.
2. Remove the upper and lower hinges
2
. You
may have to loosen the cast iron hinge pin
3
to facilitate removal of the lower hinge.
3. Remove the cast iron hinge pin
3
which is
attached by two 13 mm bolts
4
.
4. Re-install the two bolts in the original right
hand side holes. Remove the two 13mm bolts
5
from the left side and use them to loosely
install the cast iron hinge pin
3
on the left side
of the burner door.
5. On the left side of the burner door loosen the
two nuts on the burner door hinge pins
6
and
install the upper and lower hinges
2
. Tighten
the two nuts to secure the hinges and the two
13 mm bolts on the cast iron hinge pin.