4
Specifications
3. Specifications
3.1 Unit Specifications
Parameter
Unit
Value
Value
Model
--
SMVH09D-1B1A3NA
SMVH12D-1B1A3NA
Product Code
--
KEB001Z2470
KEB001Z2490
Power
Supply
Rated Voltage
V
~
220-240
220-240
Rated Frequency
Hz
50
50
Phases
--
1
1
Power Supply Mode
--
outdoor
outdoor
Cross-sectional Area of Power Cable Conductor
mm
2
1
1
Recommended Power Cable(Core)
--
3
3
Min/Max. Voltage
V
198/264
198/264
Cooling Capacity
W
2600
3500
Cooling Capacity
Btu/h
8871
11942
Min. Cooling Capacity
W
400
550
Min. Cooling Capacity
Btu/h
1365
1877
Max. Cooling Capacity
W
3300
4000
Max. Cooling Capacity
Btu/h
11260
13648
Pdesignc
KW
2.6
3.5
Heating Capacity
W
2800
3800
Heating Capacity
Btu/h
9554
12966
Min. Heating Capacity
W
400
600
Min. Heating Capacity
Btu/h
1364.8
2047.2
Max. Heating Capacity
W
4100
5130
Max. Heating Capacity
Btu/h
13989
17504
Pdesignh(Average)
KW
2.6
3.2
Cooling Power Input
W
650
875
Min. Cooling Power Input
W
150
180
Max. Cooling Power Input
W
1430
1560
Heating Power Input
W
710
975
Min. Heating Power Input
W
180
220
Max. Heating Power Input
W
1550
1800
Cooling Current
A
3.6
4.8
Heating Current
A
3.4
4.4
Rated Input
W
1550
1800
Rated Current
A
6.88
7.99
EER
W/W
4.00
4.00
EER
(Btu/h)/W
13.65
13.65
COP
W/W
3.94
3.90
COP
(Btu/h)/W
13.46
13.30
SEER
--
8.6
8.6
SCOP(Average)
--
4.6
4.6
SCOP(Warmer)
--
5.4
5.3
SCOP(Colder)
--
3.6
3.6
Energy Class
--
A+++<Cooling>/A++<Aver-
age>A+++<Warmer>A<Colder>
A+++<Cooling>/A++<Aver-
age>A+++<Warmer>A<Colder>
Air Flow Volume
m3/h
550
650
Dehumidifying Volume
L/h
0.8
1.4
Application Area
m2
12-18
16-24