- 26 -
REVERSE POLARITY
WARNING AND ERROR MESSAGE
WARNING AND ERROR MESSAGE
e6680 incorporates a variety of functions for the systems to verify
processes and the state of the electronics. In case of an error the
screen will display the cause of error and emit an audible sound.
Incorrect polarity connected.
Battery connection is interrupted.
Short-circuit of the output termination.
Input voltage incorrect.
The voltage of the battery pack has been
selected incorrectly!
The charger has malfunctioned for some
reason. Seek professional advice.
The voltage is lower than which is set.
Please check the number of cells in the
battery pack.
BATTERY CHECK
LOW VOLTAGE
BREAK DOWN
VOL SELECT ERR
INPUT VOL ERR
SHORT ERR
CONNECTION BREAK
The voltage is higher than which is set.
Please check the number of cells in the
battery pack.
Voltage of one cell in the battery pack is too
low, please check the voltage of each cell.
Voltage of one cell in the battery pack is too
high; please check the voltage of each cell.
Wrong connection of the connector detected;
please check the connector and cable.
The internal temperature is too high, please
cool down.
The processor cannot control the feeding
current, please repair it.
BATTERY CHECK
HIGH VOLTAGE
BATTERY VOLTAGE
CELL LOW VOL
BATTERY VOLTAGE
CELL HIGH VOL
BATTERY VOL ERR
CELL CONNECT
TEMP OVER ERR
CONTROL FAILURE