- 19 -
DISCHARGING OF LITHIUM BATTERY
DISCHARGING OF LITHIUM BATTERY
The value of discharge current on the left
can not exceed 1C, and the value on the
right can not be under the voltage
recommended by the manufacturer to avoid
deep discharging. Press START/ENTER for
more than 3 seconds to start discharging.
LiPo DISCHARGE
1.0A 11.1V(3S)
INC
INC
DEC
- +
INC
DEC
- +
Batt type
Stop
Start
Enter
‘>3 seconds’
This shows the real-time status of
discharging, you can press BATT
TYPE/STOP key to stop discharging.
Li3s 0.4A 12.59V
DSC 022:43 00682
BATTERY VOL ERR
CELL LOW VOL
4.14 4.16 4.09
2.18 0.00 0.00
Number
of cells
Elapsed
time
Discharge
current
Battery
voltage
Discharged
capacity
The processor monitors voltage of each cell when the battery packs
are during its “storage” and “discharging” process. If voltage of any
cell is abnormal, e6680 will show error message and terminate the
program forcibly. So if there is battery damage or disconnection, you
can see the error message and press INC to know which cell is
damaged.
VOLTAGE BALANCING AND MONITORING IN THE
DISCHARGE PROCESS
The processor detects voltage of one cell is
too low.
The 4th cell was damaged. The value of
voltage may be zero if disconnection occurs.