Lift/Drive/Steer Enable
rigger Switch
Inclined Drive/Level Drive
Switch
Emergency Stop Button/
Operation Light
Rocker Switch
Horn Pushbutton
Controller
Lift/Off/Drive Switch
Emergency Stop Button/
Operation Light
Rocker Switch
Horn Pushbutton
Lift/Inclined Drive/Level Drive Switch
Lift/Drive/Steer Enable
rigger Switch
Platform Control Console with Toggle witch
Platform Control Console with Rotary witch
KYJACK, Page 28
JIII eries
ection 1 - cheduled Maintenance
Function Tests
1.2-3 Platform Control Console
1.
Ensure base “
” emergency stop button is
pulled out.
2.
Select off/platform/base key switch to “
”
platform position.
3.
Ensure main power disconnect switch is in “ ” on
position.
wARNiNG
Ensure that you maintain three points of
contact when using the ladder to mount/
dismount platform.
4.
Use the ladder of aerial platform to access
platform.
5.
Close the gate.
6.
On platform control console, pull out “
”emergency stop button.
Test Platform Emergency top
1. Push in “
” emergency stop button
and attempt to activate any platform
function.
Result:
All selected platform functions
should not operate.
Test Enable Trigger witch
1. Without activating “
” enable trigger
switch, attempt to activate any platform
function.
Result:
All platform functions should not
operate.