KYJACK, Page 12
JIII eries
ection 5 - Procedures
ervice and Maintenance
5.3-2 LED Error Codes - Quick Reference Chart
ELP Message
LED indication
V RYTHING OK
Steady on
IN GROUND MOD !
Steady on
OV RLOAD FUNCTIONS DISABL D!
6/6
V HICL TILT D
1/1
V HICL OV RLOAD D
1/2
WAITING FOR B+ ON P2-12
5/2
ARMGUARD ACTIV !
1/3
TOO HIGH - DRIV PR V NT D
1/4
TOO HIGH - LIFT UP PR V NT D
1/5
T STING HWFS
7/8
IDL TIM OUT ACTIV !
Always off
WAITING FOR N UTRAL
5/5
L VATION SWITCH SHIFT D?
2/1
L VATION SWITCH STUCK?
2/2
NO LAST CALDAT !
6/3
LOAD NOT CALIBRAT D
6/2
DRIV /LIFT INPUTS FAULTY!
5/6
UP/DOWN S L CT INPUTS ACTIV TOG TH R
5/4
INVALID LOAD - CH CK S NSORS
6/4
H IGHT NOT CALIBRAT D
6/1
INVALID H IGHT - CH CK S NSOR
6/5
MS INPUTS FAULTY!
5/2
B+ SUPPLY TOO LOW
5/1
P4-1 OR P5-1 SHORT TO 0V?
4/1
P3-4 SHORT TO SUPPLY!
4/2
P3-4 SHORT TO 0V?
4/3
P3-4 SHORT TO SUPPLY?
4/4
P3-6 SHORT TO 0V?
4/5
P3-6 SHORT TO SUPPLY?
4/6
FAULT: BAD TILT S NSOR
7/1
FAULT: BAD HWFS
7/2
FAULT: BAD SLAV ANALOGS
7/3
FAULT: BAD STRAIN MONITORS
7/4
FAULT: BAD SLAV MICRO
7/5
FAULT: HWFS STALL D!
7/6
STARTUP!
7/7
FACTORY OV RRID
6/7
60405AA
Reading the Codes:
In order to read the fault codes, a sequence of pauses and flashes can be seen on the LED mounted on the GP102
module. he codes are continuously displayed by the LED until the fault is cleared, the GP102 reset and no longer
detects the fault, or idle timeout becomes active.
he sequence is as follows:
1. Quarter second flashes followed by quarter second pauses indicate the first digit.
2. A 1.5 second pause.
3. Quarter second flashes followed by quarter second pauses indicate the second digit
4. A 4 second pause. Repeat steps 1-4
Since the GP102 only reports one error, only one code can be read from the LED per instance. If the error is cleared
and another error is present, it will then be presented.