Load ensing ystem - CE (Continued)
KYJACK, Page 20
JIII Conventional eries
143911
ection 4 - Troubleshooting Information
ervice and Maintenance
4.3-33 Flash Code F42:Low Pressure
1. his message indicates that the pressure is too low (0.5V or less) when the elevation switch opens
during the DYNAMIC lift.
his message would occur if the pressure sensor was disconnected, or if there were some other wiring
error.
Check DIAGNOS ICS / SENSORS to check the pressure.
-
4.3-34 Flash Code F43:High Pressure
1. his message indicates that the pressure is too high (4.5V or more) when the elevation switch opens
during the DYNAMIC lift.
his message would occur if the pressure sensor was disconnected, or if there were some other wiring
error.
Check DIAGNOS ICS / SENSORS to check the pressure.
-
4.3-35 Flash Code F44:Low Pressure
1. his message indicates that the pressure is too low (0.5V or less) at a S A IC measurement point.
his message would occur if the pressure sensor was disconnected, or if there were some other wiring
error.
Check DIAGNOS ICS / SENSORS to check the pressure.
-
4.3-36 Flash Code F45:High Pressure
1. his message indicates that the pressure is too high (4.5V or more) at a S A IC measurement point.
his message would occur if the wrong pressure sensor was fitted, or if there were some other wiring
error.
Check DIAGNOS ICS / SENSORS to check the pressure.
-
4.3-37 Flash Code F46:Check Elev
1. his message indicates that the elevation switch opened more than once during the DYNAMIC lift.
4.3-38 Flash Code F47:Check Elev
1. his message indicates that the elevation switch closed more than once during the DYNAMIC lower.