It is the responsibility of the operator to read, completely understand and follow all instructions and warnings
contained in this operating manual and on the aerial platform.
F
AMILIARIZA
TION
• Test Start/Function Enable/Emergency
Power Switch (Function Enable) and All
Boom Functions
WARNING
Ensure that there are no personnel or
obstructions in test area and there is
sufficient room for boom to swing.
1. Ensure “
” emergency stop button is
pulled out.
2. Start engine.
3. Do not hold “
” start/function enable/
emergency power (function enable)
switch in function enable position. Attempt
to activate each boom and platform
switch.
Result:
All boom and platform functions
should not operate.
4. H o l d “
” s t a r t / f u n c t i o n e n a b l e /
emergency power (function enable)
switch in function enable position and
activate each boom and platform function.
Result:
Engine speed increases from idle
to intermediate. All boom and platform
functions should operate as selected.
• Test Platform Self-leveling
1. Lower boom to stowed position.
2. Adjust platform to a level position using
platform leveling switch.
3. Raise “
” and lower “
” main
boom through a full cycle.
Result:
Platform should remain level at all
time.
E m e r g e n c y
Stop
Base Control
Console
Off/Base/Platform
Key Switch
Start/Function
Enable/Emergency
Power Switch
Start/
Emergency
Power
Switch
Base/Off/
Platform Key
Switch
Base Control
Console
Function
Enable Switch
Page 30
SJ 40T & SJ 45T
SJ 61T & SJ 66T
Function Tests
Section 2 - Familiarization
Summary of Contents for SJ45T
Page 12: ...Page 12 SJ 40T SJ 45T SJ 61T SJ 66T Notes ...
Page 42: ...Page 42 SJ 40T SJ 45T SJ 61T SJ 66T Notes ...
Page 68: ...Page 68 SJ 40T SJ 45T SJ 61T SJ 66T Notes ...
Page 104: ...Page 104 SJ 40T SJ 45T SJ 61T SJ 66T Notes ...
Page 105: ...Cancer and Reproductive Harm https www p65warnings ca gov WARNING ...
Page 106: ...www skyjack com elig lift løsninger av folk som bryr seg ...