SECTION 2, Page 24
SJ 600, 800 & 1000 Series
122883AH
May 2002
Outrigger Operating Procedures
A. Before Operation
1.
Check overhead clearances and ground
obstructions. This will require the operator to
move around the platform.
2.
Check that the platform is fully lowered. (The
outrigger controls are cut out when the platform
is raised.)
3.
Check that the supporting surfaces under the
tires and outrigger pads is firm and capable of
supporting machine and related load.
DO NOT
place outrigger pad on a street drain, manhole
cover or other supported surfaces.
B. Operation - Extending The Outriggers
1.
Rotate Key Switch to “LIFT” position.
2.
Depress and hold the Enable Push-button, then
push and hold each Outrigger Up/Down Toggle
Switch to “DOWN” position extending each of
the outriggers to obtain firm ground contact.
3.
Check outrigger pad contact surface!
Make
adjustments as necessary.
4.
Again, depress and hold the Enable Push-button,
then push and hold each Outrigger Up/Down
Toggle Switch to “DOWN” position extending
each of the outriggers until the machine is
completely supported by the outriggers.
5.
Level the machine.
AGAIN, CHECK THE
OUTRIGGER PAD CONTACT SURFACE!
6.
To raise the platform, press and hold the Enable
Push-Button, then rotate the Up/Down Selector
Switch to the “
�
�
�
�
�
” position.
C. Operation - Retracting The Outriggers
1.
Fully lower the platform.
2.
Depress and hold the Enable Push-button, then
push and hold pairs (front or rear) of Outrigger
Up/Down Toggle Switches to “UP” position until
the outriggers are fully retracted.
Note
Cut out switches are used to protect the outriggers
from being damaged. If machine will not drive, visually
check to see that
ALL
outriggers are fully retracted.
D. During Operation
1.
If alarm sounds during operation, the platform
is not level.
LOWER THE PLATFORM
IMMEDIATELY!
Make the necessary
adjustments to level the machine!
Hydraulic Generator (Option)
For models with generator controls on the main
control box:
1.
To start the hydraulic generator,
Ensure the
engine is on high throttle by selecting “HIGH”
on the “Low/High Throttle Select” switch.
Select
the “LIFT” position with the “Off/Lift/Drive” key
switch, then depress hydraulic generator push-
button on the side of the operator’s control box.
The push-button will illuminate and generator
on base will start. To restore normal operation,
depress push-button again. The light in push-
button will go out and the generator will turn off.
Note
While hydraulic generator push-button switch light is
illuminated, the lift and drive circuits in the Operator’s
Control Box are cut out.
For models with generator controls on the auxilary or
optional control box:
1.
To start the hydraulic generator,
select the “LIFT”
position with the “Off/Lift/Drive” key switch. With
the engine running, flip the hydraulic generator
toggle on the auxiliary control box to the
energized position. The engine will automatically
switch to high throttle and the generator on the
base will start. To restore normal operation, flip
the toggle switch to the “OFF” position. The
generator will turn off.
Note
Activating any lift or outrigger functions will disable
the generator. Changing the keyswitch setting,
activating the emergency stop or an engine stall will
also result in stopping generator function. The
platform may be lowered during generator operation.
Electrical Inverter (Option)
1.
Turn the main disconnect switch to the “ON”
Position.
2.
Turn the “ON/OFF” switch located on the front
face of the inverter to the “ON” Position.