12.4
Warning Messages Application
When the highest bit in the Warning messages is set, a “Warning Message Application” is present.
The Application warning messages are given via parameter
Application Warnings
274, bit-coded
according to the following scheme.
Parameter
Application Warnings
273 shows the warnings in clear text on the operator panel and
the PC software tool VPlus.
Use Parameter
Application Warnings
274 to access the Application warning codes via CANopen.
Warning Messages
Bit-No.
Warning
Code
Description
0
0x0001
BELT
1
0x0002
(reserved)
2
0x0004
(reserved)
3
0x0008
(reserved)
4
0x0010
(reserved)
5
0x0020
(reserved)
6
0x0040
SERVICE
7
0x0080
User 1
8
0x0100
User 2
9
0x0200
(reserved)
10
0x0400
(reserved)
11
0x0800
(reserved)
12
0x1000
(reserved)
13
0x2000
(reserved)
14
0x4000
(reserved)
15
0x8000
(reserved)
Note:
The meaning of the individual Application Warnings is described in detail in the operating instruc-
tions.