31
SKOPE OD260
Replacement Procedures
Service Manual
Front Upstand
The front upstand is located at the bottom of the cabinet opening. The front
upstand must be in place at all time as it directs the air curtain.
To replace the front upstand
Vertical Bumpers
A plastic bumper strip is fitted to the vertical extrusions on each side of the
front of the cabinet. These bumpers provide general impact protection while
the cabinet is in use. If necessary, the bumpers can be replaced.
To replace the vertical bumpers
Wheels
The chiller is fitted with 4 castors which can be removed and replaced if
necessary. The wheels swivel but do not lock. Use the stabiliser feet to lock
the chiller in position (see page 26).
The wheels can be removed and replaced.
Honeycomb Air Grille
The chiller is fitted with a honeycomb air grille at the front of the cabinet
interior ceiling, which directs the air curtain down the front of the cabinet
opening. The honeycomb can be removed for cleaning or replacing.
To remove the honeycomb, unscrew the cabinet interior ceiling top duct.
When refitting, ensure the honeycomb site sits flat and cannot be easily
removed. When pushed gently it should not move.
1. Isolate the chiller from the mains power supply.
2. Remove the existing front upstand by undoing the 4 screws (2 at each end)
of the upstand.
3. Fit the new front upstand.
4. Reconnect the cabinet to the power supply and reassemble.
1. Isolate the chiller from the mains power supply.
2. Remove the lid from the top of the cabinet.
3. Peel the existing vertical bumper from the aluminium extrusion.
4. Slot the new vertical bumper into the extrusion.
5. Trim the vertical bumper to the correct size.
6. Reassemble the chiller and reconnect to the power supply.