![Skope OD260 Service Manual Download Page 40](http://html1.mh-extra.com/html/skope/od260/od260_service-manual_1289197040.webp)
40
Replacement Procedures
Service Manual
SKOPE OD260
Cleaning
Ensure the cabinet is disconnected from the mains power supply before
cleaning the cabinet.
Cabinet
When necessary, wipe both the interior and exterior of the cabinet with warm
soapy water and a soft cloth. Do
not
use chemical cleaners.
Condenser
Coil
To ensure trouble-free performance, the condenser coil must be kept clean.
We strongly urge monthly cleaning with a soft brush to remove dust and fluff.
A thorough cleaning is required by qualified service personnel every six
months. The condenser coil
must
be kept clean for efficient and reliable
operation.
To clean the condenser coil
CAUTION
Do
NOT
wash any liquid down into the refrigeration system,
as this could lead to refrigeration failure.
WARNING
Disconnect the chiller from the power supply before cleaning
the condenser coil.
1. Disconnect the cabinet from the power supply.
2. Remove the front panel
from the cabinet by
undoing the fixing screws
near the bottom of the
panel and lifting it up and
off the cabinet.
3. Brush the condenser coil
with a soft brush
4. Refit the front panel and reconnect to the power supply.
Front Panel
Condenser coil