Section 06
ELECTRICAL
Subsection 06
(TESTING PROCEDURE)
06-06-9
M: Male
F: Female
NOTE:
It is important to take note that voltage measurements must be taken while starting the vehicle using the
manual starter.
Voltages obtained upon starting are proportional to the force applied onto the manual starter. A low
voltage is therefore normal under a low cranking force.
Perform testing in the prescribed order and replace any parts not performing according to specifications.
It is important to resume all tests when replacing a component.
If not specified, the probe connecting sequence is not important.
LIGHTING SYSTEM TESTING (CK3 series — 290 W)
Part
Test to be
performed
Wire
color
Multimeter
probe
connection
Resistance
Ω
Voltage V
Note
Value
(Ohms)
Multimeter
scale
Value
(Volts)
Multimeter
scale
Lighting
generator
coil
Output
YL and
YL
2-01B-F
and
2-01C-F
00.0 -
00.5
00.0
Ω
3.0 - 7.0
00.0
VAC
Coil
insulation
YL and
engine
2-01(B,C)-F
and
engine
0.L
00.0
M
Ω
—
—
The term "engine" refers to the
engine metal parts connected to
the magneto housing.
Ground
continuity
BK and
engine
2-01A-F
and
engine
00.0 -
00.5
00.0
Ω
—
—
Summary of Contents for Formula MACH 1
Page 1: ......
Page 277: ...FORMULA 111 600 600 R 600 LT 700 700 R MACH 1 1 R ANNEX 1...
Page 278: ......
Page 279: ......
Page 280: ......
Page 281: ......
Page 282: ......
Page 283: ...MACH Z Z R Z LT Z LT R ANNEX 2...
Page 284: ......
Page 285: ......
Page 286: ......
Page 287: ......
Page 288: ......
Page 289: ...GT 700 ANNEX 3...
Page 290: ......
Page 291: ......
Page 292: ......
Page 293: ......
Page 294: ......
Page 295: ......
Page 296: ...GT SE ANNEX 4...
Page 297: ......
Page 298: ......
Page 299: ......
Page 300: ......
Page 301: ......
Page 302: ......
Page 303: ......
Page 304: ......