Quick Setup/Installation Guide for Lubrication Monitor Controller LMC 301
951-150-029-EN
11
X1
X1
4.7.2 Power supply
100 to 240 VAC and 24 VDC
Terminal diagram
100 to 240 V AC, Fig. 6
)
see Figure 4, item 1, and Fig. 6
Terminal diagram 24 VDC, Fig. 7
• Connect customer-provided cable for
power supply acc. to terminal diagram
24 VDC, Fig. 7.
• Connect customer-provided cable for power
supply acc. to terminal diagram
100 to 240 VAC, Fig. 6.
)
The 24 VDC is generated internally. Do not
connect externally generated 24 VDC to ter-
minal
+
or terminal
-
.
)
see Figure 5, item 1, and Fig. 7
4.7.3 Terminal strip for relay outputs
)
see Figures 4/5, item 4, and Figures 9 to 10
Connections in conjunction
with load switching relay
max. 8 A
Terminal diagram for relay outputs, Fig. 9
O 4
O 4
O 3
O 3
O 2
O 2
O 1
O 1
O 8
O 8
O 7
O 7
O 6
O 6
O 5
O 5
O = O u t p u t
Terminals
O3 to O8
max. 8 A
Connections in conjunction
with load switching relay
max. 8 A
X4
ATTENTION!
You can run each terminal block (4.1 or 4.2)
only with one operating voltage (24VDC or
100 to 240 VAC). Do not mix 2 different
voltages together on 1 terminal block.
4.7.4 Load switching relay
)
see Figures 4/5, item 11, and Fig. 8
Proposal Load switching relay, Fig. 8
• Connect (loop) customer-provided load
voltage cable to both terminals of the load
relay.
O 3
O 2
O 2
O 1
O 1
Input 230 VAC
max. 15 Ampere
Input 230 VAC
max. 8 Ampere
Input 230 VAC
max. 8 Ampere
Input 230 VAC
max. 15 Ampere
M
Output
max. 8 Ampere
M
Relay 2
Relay 1
Connection up to
max. 8 amperes
Load relay
controlled
directly
X5
Connection example for relay outputs, Fig. 10
O 4
O 4
O 3
O 3
O 2
O 2
O 1
O 1
O 8
O 8
O 7
O 7
O 6
O 6
O 5
O 5
G r
ound
Power
Signal
monitoring
Reversing valve
Pump motor
Connection
max.
8 amperes
X6
4.1
4.2
4.1
4.2