A
LL
M
2
3
5
6
7
4
8
10
9
Diagram
Centro-Matic system schematic with PS pump
P.S.
or
P.T.
To atmospere
To bearings
End of line
P.S. or P.T.
optional
PS pump
To bearings
Note: For proper operation of Centro–Matic systems, before next lubrication cycle, vent pressure at end of line should be:
– below psi
(62 bar)
for SL–V and SL–V XL type injectors
– below psi
(41 bar)
for SL– type injectors
– below psi
(13.8 bar)
for SL–/ type injectors
Item
Description
Pump housing ( pump elements)
Motor
Controller, key board with display
Internal pressure switch (P.S.) or pressure transducer (P.T.)
Internal vent valve
Reservoir with low level control
Pressure relief, psi
(345 bar)
external
High pressure supply line
Injectors, SL-V, SL- or SL-, SL- and SL-V XL injectors
Pressure switch (P.S.) or pressure transducer (P.T.) external optional
A
Power supply ( V
OR V AC, optional)