MIN
1
2
3
4
5
6
7
8
9
10
11
Item
Description
Reservoir
Top lid
Stationary paddle
Stirring paddle
Mounting plate
Pump elements
Pump housing
Refill grease fitting
Keypad
Pump outlet
Relief valve
Fig.
Single–line pump PS
Note: Low–level control
(
† Fig.
and
Fig.
,
page
)
System operation
Overview
Only difference between models -*
and is model -* comes with
reservoir one third full of NLGI grease. This
manual will describe model -*.
Model -* initiates lube cycle on a
count pulse instead of time between lube
cycles. Model -* is set for one
count to start a lube cycle. This one count
feature allows customers machine controller
to initiate lube cycles. This one count is a
V
pulse lasting from to seconds.
Pump operates on V
.
Alarm contacts are set to open position.
When power is applied, alarm contacts will
close. If alarm condition occurs, alarm
contact will open.
Changing of programming parameters,
via keypad, is prohibited due to setting of
internal jumper pin. Refer to
Jumper
settings for PS pump PCB, page
.
On power up model will wait for V
pulse before initiating lube cycle. If pump
was in lube cycle when power was turned off
it will start with lube cycle upon power up.
Pump PS
• Pump greases up to NLGI (per
approved list) at temperatures from
– to + °F
(340 to +70 °C).
• Develop maximum pressure up to
psi
(240 bar)
with pressure
switch and up psi
(317 bar)
with
pressure transducer.
Reservoir sizes
• l transparent plastic reservoir
• l transparent plastic reservoir
• l transparent plastic reservoir
• l transparent plastic reservoir
Electrical connection
• For industrial / V AC applications
PS pumps are provided with -pole
square type connector. Electric cable is
provided by installer.
• For mobile applications PS pumps are
equipped with electric cable ft
(10 m)
and –pole bayonet type connector.
C AUTION
Always use supply line hose and fittings
appropriate for programmed/set system
pressure.
Failure to comply may result in
personal injury or damage to system
components.
*
Indicates change